Tucker GmbH,
Mail / Post:
Max-Eyth-Str.1, 35394 Gießen, Germany
Stud welding unit N800i
As of 24.08.2021
Manual part number: BE 1227
53
6.3.9 Stud ExpertTM weld table
The following Stud Expert weld table is programmed into the inverter controls. It
allows for automatic weld settings based on stud type and diameter.
Note!
There are conditions that will filter the table for selection, or reveal
only a subset of the table to the user
Unit selection (F24)
‐
If unit is set to metric, only metric diameters are available. If
unit is set to English, only diameters in inches are available. If unit is set to both,
then both will be available for selection.
In the case of the N800i, studs requiring >800A will not appear in the list for
selection.
Short cycle mode (F30)
‐
If configured for short cycle mode, studs requiring
>=100ms will not display in the list. Conversely, in drawn
‐
arc mode, studs requiring
<100ms will not display in the list.
lstandard
tstandard
laluminium
taluminium
Process
3mm Pitch Base
200,
100,
100,
160
Drawn Arc
3mm Full Base
220,
100,
110,
170,
Drawn Arc
3mm IS
‐
Bolzen
200,
150,
200,
150,
Drawn Arc
3mm SC
‐
Bolzen
M3
400,
15,
400,
15,
Short Cycle
3/16ʺ Pitch Base
280,
140,
150,
230,
Drawn Arc
3/16ʺ Full Base
310,
150,
160,
250,
Drawn Arc
4mm Pitch Base
240,
120,
130,
200,
Drawn Arc
4mm Full Base
270,
130,
140,
220,
Drawn Arc
4mm IS
‐
Bolzen
280,
200,
280,
200,
Drawn Arc
4mm SC
‐
Bolzen
M4
500,
15,
500,
15,
Short Cycle
5mm Pitch Base
290,
140,
150,
240,
Drawn Arc
5mm Full Base
320,
160,
170,
270,
Drawn Arc
5mm IS
‐
Bolzen
350,
230,
350,
230,
Drawn Arc
5mm SC
‐
Bolzen
M5
600,
20,
600,
20,
Short Cycle
5mm ATC M5
600,
20,
600,
20,
Short Cycle