Tucker GmbH,
Mail / Post:
Max-Eyth-Str.1, 35394 Gießen, Germany
Stud welding unit N800i
As of 24.08.2021
Manual part number: BE 1227
55
lstandard
tstandard
laluminium
taluminium
Process
7/16ʺ Full Base
720,
400,
380,
730,
Drawn Arc
12mm Pitch Base
680,
380,
370,
690,
Drawn Arc
12mm Full Base
780,
440,
420,
820,
Drawn Arc
12mm MM12, S12
950,
450,
950,
450,
Drawn Arc
12mm SC
‐
Bolzen
M12
1300,
50,
1300,
50,
Short Cycle
1/2ʺ Pitch Base
730,
410,
390,
750,
Drawn Arc
1/2ʺ Full Base
840,
480,
450,
890,
Drawn Arc
13mm Pitch Base
750,
420,
400,
770,
Drawn Arc
13mm Full Base
860,
500,
460,
920,
Drawn Arc
14mm Pitch Base
820,
470,
440,
860,
Drawn Arc
14mm Full Base
860,
500,
460,
920,
Drawn Arc
15mm Pitch Base
890,
510,
480,
960,
Drawn Arc
15mm Full Base
1030,
610,
550,
1160,
Drawn Arc
5/8ʺ Pitch Base
960,
560,
510,
1050,
Drawn Arc
5/8ʺ Full Base
1110,
660,
590,
1270,
Drawn Arc
16mm Pitch Base
970,
560,
520,
1060,
Drawn Arc
16mm Full Base
1120,
670,
600,
1280,
Drawn Arc
16mm S16, SD16
1400,
550,
1400,
550,
Drawn Arc
17mm Pitch Base
1050,
610,
560,
1170,
Drawn Arc
17mm Full Base
1220,
730,
650,
1420,
Drawn Arc
18mm Pitch Base
1130,
670,
600,
1290,
Drawn Arc
18mm Full Base
1310,
790,
700,
1560,
Drawn Arc
19mm Pitch Base
1210,
720,
640,
1410,
Drawn Arc
19mm Full Base
1420,
860,
750,
1710,
Drawn Arc
3/4ʺ Pitch Base
1210,
730,
650,
1410,
Drawn Arc
3/4ʺ Full Base
1420,
860,
750,
1720,
Drawn Arc
If the vertical position is selected, selection of some studs will provide a 10%
increase in current and 15% reduction of weld time from what is shown here.
Summary of Contents for N800iTM