Stud welding unit N800i
As of 24.08.2021
Manual part number: BE 1221
76
Tucker GmbH,
Mail / Post:
Max-Eyth-Str.1, 35394 Gießen, Germany
7.
Function Codes
NOTE!
Contact the factory or Nelson representative if F25 shows a different version for F code info not in the table
below.
The table below is for firmware version 1.05 only
F
code Description
Possible Values
Default
Unit
Notes
F0
Language
ENGLISH,
GERMAN,
ITALIAN,
SPANISH,
FRENCH
ENGLISH x
F1
Error Display
E--- to E018
E---
x
See below for error defines
F2
Plunge short circuit
on-time
0 to 150
100
ms
When short cycle mode is enabled, this defaults to 20ms. When
disabled, this defaults to 100ms.
F3
Stud Expert Mode
easy access
POSTION, MA-
TERIAL,
PROCESS
POSITION x