Stud welding unit N800i
As of 24.08.2021
Manual part number: BE 1221
83
Tucker GmbH,
Mail / Post:
Max-Eyth-Str.1, 35394 Gießen, Germany
F
code
Description
Possible Values
Default
Unit
Notes
F40
Pulse Cleaning Time
to Subtract for Each
Pulse
0 to 500
10
ms
Time to remove from the main weld time per pulse done prior to the
weld.
F41 Passing Weld
Counter
0 to 4.3B
0
X
When process
monitor is used, this holds a count of ‘passing’ welds.
Hold the time down arrow to reset.
F42 Failed Weld Counter 0 to 4.3B
0
X
When process monitor is used, this holds a count of ‘failed’ welds. Hold
the time down arrow to reset.
F43 Diagnostic Data
#Phases, PWM
AVG, ABORT
code, Capacitor
imbalance or Duty
Cycle
#Phases X
This gives extra diagnostic data after each weld. If the power unit is at
the maximum output in voltage and current, PWM AVG will be 100%.
F44 Preset Bank
0 to 3
1
X
This determines which preset the 0-9 buttons are accessing. By
selecting the preset bank, up to 40 presets can be ac- cessed. For
example, if the preset bank is set to 0, preset button 5 will access preset
5. If preset bank is set to 1, preset button 5 will access preset 15. This F
code changes automatically depending on short cycle mode and the gun
inter- face installed in the power unit.
F45 Calibration Offset
Value
0 to 250
50
X
Used by manufacturing. Do not change
Summary of Contents for N800iTM
Page 18: ......