Tucker GmbH,
Mail / Post:
Max-Eyth-Str.1, 35394 Gießen, Germany
Stud welding unit N800i
As of 24.08.2021
Manual part number: BE 1227
90
Error Number
Error Display
What this really means
Fatal
–
meaning you
have to power down
to reset. Otherwise,
you weld again to
reset.
Likely problem
E011
UNIT TOO HOT
PLEASE WAIT
The thermal sensor was
tripped. This error will
dis‐
appear when the sensor re‐
sets.
Thermal sensor on output PCB heatsink
has been activated. Wait for it to cool
down.
‐See
troubleshooting‐
E012
SHORT CIRCUIT‐
CHECK GUN LIFT
SET‐
TING
If a short circuit was
detected for at least 100ms,
the weld aborts to protect
the power unit.
Check the gun lift setting. Under normal
welding conditions, this should not
hap‐
pen.
‐See
troubleshooting‐
E013
WELD FAILED
–
OUT
OF TOLERANCE
The last weld was out of
to‐
lerance from the target weld
by weld energy or drop ti‐
me.
Compare actual time, current, voltage, and
drop time to find cause. A new target can
also be set.
‐See
troubleshooting‐
E014
NO STUD HIT
DETEC‐
TION
The stud is expected to hit
the workpiece after the gun
coil is de‐energized, but be‐
fore the main current is
tur‐
ned off. If it is not detected,
this error will occur.
Incorrect weld parameter setup. Check
drop time, weld time, and plunge time.
Press LOCK button to clear error.
‐See
troubleshooting‐
Summary of Contents for N800iTM