background image

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

OPERATING INSTRUCTIONS 

 

 

 

You want your generator to be ready when you need it -- so, it is important to perform the following steps once a month: 

 

Start and run generator power through your transfer switch circuits. 

 

Keep your fuel tank filled with fresh fuel. 

 

With  your  Reliance  Controls 

Easy/Tran  TF

  installed,  it  is  not  necessary  to  turn  off  any  of  your  load  center  breakers  when  starting 

your generator, even when utility power is fully functional.  This is because the double throw break-before-make action of the furnace 

relay prevents feeding generator power to the utility and, conversely, prevents feeding utility power back to your generator. 

 

A.  Transferring from Utility Power to Generator Power in an Emergency 

 

1. 

Make sure that the toggle switch on the 

Easy/Tran TF

 is in the LINE position. 

2. 

Plug the appropriate extension cord into the appropriate receptacle on your generator. 

3. 

Plug the female end of the extension cord into the power inlet box. 

4. 

Start your generator outdoors and let it warm to a point where it is running evenly. 

5. 

Turn the toggle switch on the furnace relay to the GEN position. 

 

B.  Transferring back to Utility Power When the Power Is Restored 

 

1. 

Move the toggle switch on the 

Easy/Tran TF

 back to the LINE position. 

2. 

Turn off your generator. 

3. 

Unplug the extension cord. 

 

 

SPECIFICATIONS  

 

 

 

 

  

 

TF151 & TF151W 

TF201 & TF201W 

Maximum Watts 

 

1875 

2500 

Maximum Combined Load @ 125 Volts AC (Amps) 

 

15 

20 

Maximum Load per Circuit from Generator (Amps) 

 

15 

20 

Maximum Load per circuit from Load Center (Amps) 

 

20 

20 

Wattmeters 

 

No 

No 

Number of Knockouts Available 1/2" or 3/4" 

 

Cabinet Dimensions H x W x D (inches) 

 

7 1/2" x 7" x 4 1/2" 

7 1/2" x 7" x 4 1/2" 

Cabinet Type (NEMA) 

 

 

 

 

 

 

Five Year Limited Warranty 

 

Reliance  Controls  Corporation  (“Reliance”)  warrants  this  Protran®  Manual  Transfer  Switch  (“Switch”)  to  be  free  from  failure  to  perform  as 
intended due to defects in materials and workmanship for a period of five (5) years from date of manufacture, provided the Switch has been 
installed  and  used  in  accordance  with  manufacturer’s  instructions  and  has  not  been  subjected  to  misuse,  alteration,  accident,  or  repair  not 
performed by Reliance.  If, within such warranty period, the original purchaser gives written notice to Reliance at the address shown below and 
the  Switch  has  been  proven  to  Reliance’s  reasonable  satisfaction  to  be  defective,  then  Reliance  at  its  sole  option  shall  either:  (i)  supply  a 
replacement  component(s)  for  the  defective  component(s)  or  (ii)  repair  or  replace  the  Switch.  Reliance’s  obligation  is  strictly  limited  to  said 
repair or replacement of the Switch and Reliance shall not be liable for any incidental, special or consequential damages.  The cost of labor to 
remove or install a replacement component or Switch is not included in this warranty.  The foregoing warranty is exclusive and in lieu of all 
other  expressed  or  implied  warranties,  if  any,  including  but  not  limited  to  implied  warranties  of  merchantability  and  fitness  for  a  particular 
purpose.  Reliance strongly recommends that the purchaser seek the advice of a licensed electrician to determine the suitability of this product, 
and for its proper installation in accordance with all applicable state and local building codes.  This warranty gives you specific legal rights, and 
you may have other rights which vary from state to state. 
 

Summary of Contents for Reliance Controls Easy/Tran TF151

Page 1: ...Transfer Switch 4 Yellow Wire Connectors SAFETY SYMBOLS USED IN THIS MANUAL Danger indicates an imminently hazardous situation that if not avoided could result in death or serious injury Warning indicates a potentially hazardous situation that if not avoided could result in death or serious injury Caution indicates a potentially hazardous situation that if not avoided may result in minor or modera...

Page 2: ... either GEN generator or LINE utility as the power source for the furnace circuit breaker that has been wired through the transfer switch The OFF position generally is not used as a switch in the OFF position removes the furnace circuit both from generator and utility power Pre Wired Flexible Conduit Whip Contains two hot one neutral and one ground wire required to make connections between the fur...

Page 3: ... the power inlet box connect the green wire in the transfer switch to the green wire from the power inlet box F Tilt front plate back into the cabinet and attach with the screws in Step 1 II Connecting Models TF151 and TF201 These models should be connected by a licensed electrician or heating contractor since they involve mounting on the furnace and making the electrical connections on or in the ...

Page 4: ...wire that is attached to it 2 Find the black and red wires from the Easy Tran TF 3 Cut the red wire at a length convenient for it to reach to the furnace circuit breaker Strip 5 8 from the end of the wire Connect the red wire to the furnace circuit breaker and retighten the screw on the breaker 4 Cut the black wire from the transfer switch to a length convenient for attaching it to the wire you re...

Page 5: ...Available 1 2 or 3 4 2 2 Cabinet Dimensions H x W x D inches 7 1 2 x 7 x 4 1 2 7 1 2 x 7 x 4 1 2 Cabinet Type NEMA 1 1 Five Year Limited Warranty Reliance Controls Corporation Reliance warrants this Protran Manual Transfer Switch Switch to be free from failure to perform as intended due to defects in materials and workmanship for a period of five 5 years from date of manufacture provided the Switc...

Page 6: ...sfert de Circuit unique de 20 ampères TF201 1 Connecteurs de fil jaune SYMBOLES DE SÉCURITÉ UTILISÉS DANS CE MANUEL DANGER indique une situation dangereuse imminente qui si ne pas évitée peut entraîner des blessures graves voire la mort Avertissement indique une situation potentiellement dangereuse qui si ne pas évitée pourrait entraîner des blessures graves ou la mort Attention indique une situat...

Page 7: ...ctionner les GEN générateur ou ligne utilitaire comme source d alimentation pour le disjoncteur de la fournaise qui a été reliée par l intermédiaire de l interrupteur de transfert Position d arrêt en général ne sert pas comme un interrupteur en position OFF supprime le circuit four du générateur et réseau électrique Pré câblé Conduit Flexible fouet Contient deux chauds un neutre et un conducteur d...

Page 8: ...r de transfert au fil blanc de la boîte d entrée de puissance connecter le fil vert dans le commutateur de transfert au fil vert de la boîte d entrée de puissance L Inclinez le platine dans l armoire et fixer avec les vis desserrées à l a II Connexion au fourneau Ce type de connexion doit être rempli par un électricien ou un entrepreneur en chauffage puisqu ils impliquent de montage sur le four et...

Page 9: ... 1 Couper le disjoncteur du four Débrancher le fil qui est attaché à elle 2 Trouver les fils noirs et rouges de la TF Easy Tran 3 Coupez le fil rouge à une longueur pratique pour parvenir au disjoncteur du four Bande de 5 8 de l extrémité du fil Branchez le fil rouge sur le disjoncteur du four et resserrez la vis sur le disjoncteur 4 Couper le fil noir de l interrupteur de transfert sur une longue...

Page 10: ...re de charge ampères 20 20 Wattmètres No No Nombre d entrées défonçables disponible 1 2 ou 3 4 2 2 Armoire Dimensions H x l x P po 7 1 2 x 7 x 4 1 2 7 1 2 x 7 x 4 1 2 Armoire Type NEMA 1 1 Garantie limitée de cinq ans Reliance Controls Corporation Reliance garantit cet Protran manuel commutateur de transfert Switch sont exempts de défaut de fonctionner comme prévu en raison de défauts de matériaux...

Page 11: ...erencia del solo circuito de 20 amperios TF201 2 conectores de cable amarillo SAFETY SYMBOLS USED IN THIS MANUAL PELIGRO indica una situación inminentemente peligrosa que si no se evita podría causar la muerte o lesiones graves ADVERTENCIA indica una situación potencialmente peligrosa que si no se evita podría causar la muerte o lesiones graves Precaución indica una situación potencialmente peligr...

Page 12: ... disyuntor de calentador que ha sido cableado a través del interruptor de transferencia La posición de apagado generalmente no se utiliza pues un interruptor en la Látigo flexible precableado del conducto Contiene dos cables calientes uno neutro y un cable de tierra requeridos para hacer conexiones entre el interruptor de transferencia del horno y el disyuntor del calentador en su centro de carga ...

Page 13: ...a en el calentador III conexión de los modelos TF151AW y 201AW Cómo conectar el látigo flexible de conductos a su centro de carga por favor no intente doblar el látigo flexible de conductos más allá de sus capacidades estructurales Configure la iluminación alimentada por batería para iluminar claramente su área de trabajo Turn off the main utility breaker Figure 3 1 Retire la cubierta de su centro...

Page 14: ...ros y rojos del Easy Tran TF 3 Corte el alambre rojo en una longitud conveniente para que alcance al disyuntor del calentador Tira 5 8 del extremo del cable Conecte el cable rojo al disyuntor del horno y vuelva a apretar el tornillo del interruptor 4 Corte el cable negro del interruptor de transferencia a una longitud conveniente para fijarlo al alambre que usted quitó del disyuntor del calentador...

Page 15: ...isponibles 1 2 o 3 4 2 2 Dimensiones del gabinete H x W x D pulgadas 7 1 2 x 7 x 4 1 2 7 1 2 x 7 x 4 1 2 Tipo de gabinete NEMA 1 1 GARANTÍA LIMITADA DE CINCO AÑOS La Corporación Controls de dependencia confianza garantiza que este interruptor de transferencia manual protran switch esté libre de fallas para realizarse como se ha previsto debido a defectos en materiales y mano de obra por un período...

Page 16: ...Reliance Controls Customer Service 800 439 5745 Website www reliancecontrols com Reliance Controls Service à la clientèle 800 439 5745 Website www reliancecontrols com IITWF 12 12 17 ...

Reviews: