background image

 

4.3in

108.15mm 

 

2.3in

59mm  

0.27in

6.76mm

0.27in

6.8mm

1.7in

44mm

2.8in

70mm

XR-YM – YOKE MOUNT INSTALLATION

Refer to alternate instructions if using Conduit, Hook, Pole 

or Wall Mount

STEP 1.

Inspect shipping package and contents to ensure no damage has occurred 

during shipping.  

STEP 2.

Make wiring connections from branch circuit conductors to factory 

provided lead wires using one of the 3/4" NPT threaded entries. Follow 

wiring method requirements of the Canadian Electrical Code or National 

Electrical Code for the specific hazardous location of the installation. 

NOTE:

To aid in assembly and provide protection against ingress, use of a petrolatum or 

soap thickened mineral oil based thread lubricant/sealant is necessary.

Un-used conduit opening must be plugged to maintain the integrity of the 

enclosure.

STEP 3.

Loosely assemble Yoke mount with carriage bolts on inside and washers 

and nuts on the outside. 

NOTE: 

Depending on which mounting hole is used in the curved slot, the luminaire may 

be configured for an upward or downward adjustable swing. 

STEP 4.

Thread installed wiring through openings in yoke mount cheek plate and 

yoke mount bracket. Mount yoke assembly to luminaire using 4x M6 Socket 

Head Cap Screws and Washers (Provided). Torque fasteners to 5 Nm (45 

in-lbs).

STEP 5.

Mount luminaire assembly to desired location using 4x 1/4-20 OR M6 

Screws or Bolts (Not Provided).

STEP 6.

Adjust and aim luminaire to desired position. Torque hardware nuts to 9 

N-m (80 in-lbs).

STEP 7.

Resume installation instructions provided with luminaire. (STEP 4 in XR 

Installation Instructions from the Surface/Ceiling Mount installation 

provided with Luminaire).

Step 5

Step 3

This XR-YM kit is intended for use with UL Listed XR luminaire as 

marked on the luminaire nameplate.  

Accessory Package Contents

INSTALLATION STEPS

XR-YM

PART NAME

QTY

1

1

1

4

4

4

4

YOKE MOUNT A

YOKE MOUNT B

CHEEK PLATE

1/4-20 HEX NUT

1/4" FLAT WASHER

1/4-20 x 0.5in CARRIAGE BOLT

M6 x 25mm HEX HEAD CAP SCREW

TM

Nemalux

I N D U S T R I A L

XR-HAZ

rrev. A-13

8-14

www.nemalux.com  |   sales@nemalux.com  |   Tel 403•242•7475  |   Fax 403•243•6190 

MADE IN CANADA

WARNING:

The XR head must not face upwards 

any degree beyond the horizontal 

position for Class II, Division 2, Zone 

22 and Class III hazardous location 

installations.

ATTENTION:

Le luminaire XR ne doit pas être orienté 

vers le haut à un degré quelconque au-

delà de la position horizontale pour les 

installations en zones dangereuses de 

classe II, division 2, zone 22 et classe III.

LIGHT

BEAM

HORIZON

WARNING

Summary of Contents for XR-HAZ

Page 1: ...ed to a minimum of 90 C Class 1 Wiring only All supply field wiring must be rated 300V minimum for luminaires with suffix AC 600V minimum for luminaires with suffix HV Ambient Temperature Range Class...

Page 2: ...xterior lens surface with damp cloth only SURFACE CEILING MOUNT INSTALLATION Refer to alternate instructions if using Conduit Hook Wall Pole or Yoke Mount Step 2 Step 3A Step 3B TM Nemalux I N D U S T...

Page 3: ...assification of the area of installation Connect Violet and Gray driver lead wires to 0 10VDC control wiring LED Drivers will source a combined maximum of 200 A for control needs 0 10V Controller must...

Page 4: ...ot to be used WIRING DIAGRAM PS 1 GROUND Factory BLACK LINE WHITE NEUTRAL GREEN GROUND VIOLET DIM GREY DIM BLACK WHITE GREEN VIOLET GREY TM Nemalux I N D U S T R I A L XR HAZ rev A 13 4 14 www nemalux...

Page 5: ...stallation instructions provided with luminaire STEP 4 in XR Installation Instructions from the Surface Ceiling Mount installation provided with Luminaire SET SCREW This XR PM kit is intended for use...

Page 6: ...to mount main body Torque to 1 7 N m 15 in lbs STEP 6 Mount luminaire assembly to desired location using 4x 1 4 20 OR M6 Screws or Bolts Not Provided STEP 7 Resume installation instructions provided w...

Page 7: ...sses on the XR cheek plates should register inside of the large circular holes on the XR high vibration yoke mount arms Rotate luminaire to aim in the desired direction and fasten in place using 2x M6...

Page 8: ...nt yoke assembly to luminaire using 4x M6 Socket Head Cap Screws and Washers Provided Torque fasteners to 5 Nm 45 in lbs STEP 5 Mount luminaire assembly to desired location using 4x 1 4 20 OR M6 Screw...

Page 9: ...ly and provide protection against ingress use of a petrolatum or soap thickened mineral oil based thread lubricant sealant is necessary Un used conduit opening must be plugged to maintain the integrit...

Page 10: ...ate steel cable or chain through the outer band of the unit and fastening a closed loop Secondary safety hardware must be rated for a minimum of 110lbs Install remaining loop of secondary safety chain...

Page 11: ...dy near AC input Secure the surge protector and driver lead wires together as close to the origin of the driver lead wires as possible using the provided zip tie STEP 4 Wire according to wiring instru...

Page 12: ...s from LED Drivers 3 Connect Green wire from surge protector to splice or terminal connected to Grounding branch circuit conductor and green lead from luminaire case PS 1 GROUND Factory BLACK WHITE WH...

Page 13: ...provided zip tie STEP 4 Wire according to wiring instructions on Page 14 14 Refer to NEC CEC codes and follow all applicable local standards STEP 5 Close XR Wiring Cover Ensure the retention cable is...

Page 14: ...conductor and White leads from LED Drivers 3 Connect Green wire from surge protector to splice or terminal connected to Grounding branch circuit conductor and green lead from luminaire case TM Nemalux...

Reviews: