Version: 2.0
KEN002PW18 25.11.2019
[ EN
●
31 ]
VACCUM SWITCH
The STOVE has s vacuum switch located behind the left door, fastened to the base. If a low pressure is crea
-
ted in the firebox by a leak, opening the front door, a blocked flue, or unsealed ash drawer(some model), the
vacuum switch will sense it and cause the stove to go into a shutdown mode by showing E5.
AUGER AND AUGER MOTOR
The 2 RPM auger motor turns the auger, lifting pellets up the auger tube. The pellets are then dropped down a
tube and into the firepot. The auger motor is controlled by the control board.
PROTECT TEMPERATURE SENSOR TO AVOIDOVERHEATING
A safety temperature switch switches the stove off automatically if it overheats,. After the stove has cooled
down meanwhile it shows E6. Whether the heating operation is continued or not depends on the remaining
embers in the fire pan. After you remove the Error Code by "Okay button" , If re-ignition does not occur when
the fuel supply recommences, then the out of operation program (cleaning , lag phase) is carried out. Accor-
ding to the pre-set mode the stove must be re-started.
CAUTION: If overheating has occurred then maintenance or cleaning work must be carried out.
EXHUASTED TEMPERATURE SENSOR FUNCTION AS LOW TEMPERATURE SWITCH OFF
If the stove cools down below a minimum temperature, then the stove will switch off. This switch off can also
occur if pre-heating is too slow.
5. MAINTENANCE AND CLEANING
5.1. DAILY OR WEEKLY CLEANING PERFORMED BYTHE USER
5.1.1. BEFORE EACH IGNITION
Clean the ash "F" and any deposits in the brazier that could clog the air passage holes.
In case of pellets running out in the tank or of a failed ignition alarm (E2), there could be unbent pellets in the
brazier. Always empty the residue in the brazier before each ignition.
IMPORTANT!
All cleaning of all parts must be carried out with the stove completely cold and
unplugged.
The stove does not need much maintenance if used with certified quality pellets
.
IF IGNITION FAILS (E2), IT IS IMPORTANT TO REMOVE THE PELLETS LEFT IN THE BRAZIER AFTER
REPEATING THE IGNITION OPERATION.
For the brazier to be cleaned properly, remove it from its housing completely and thoroughly clean all the holes
and the grate on the bottom. If good quality pellets are used, you will normally only need to use a brush to
restore the optimal operating conditions of the component.
REMEMBER THAT ONLY A CORRECTLY POSITIONED AND CLEAN BRAZIER CAN GUARANTEE IGNITION
AND OPTIMAL OPERATION OF YOUR PELLET PRODUCT.
Example of clean grate
Example of dirty grate
Summary of Contents for PW18
Page 38: ...Version 2 0 KEN002PW18 25 11 2019 EN 38...
Page 39: ...Version 2 0 KEN002PW18 25 11 2019 EN 39 DECLARATION OF PERFORMANCE AND TEST REPORT...
Page 40: ...Version 2 0 KEN002PW18 25 11 2019 EN 40...
Page 41: ...Version 2 0 KEN002PW18 25 11 2019 EN 41...
Page 78: ...DE 78 Version 2 0 KEN002PW18 25 11 2019...
Page 79: ...DE 79 Version 2 0 KEN002PW18 25 11 2019 LEISTUNGSERKL RUNG UND PR FBERICHT...
Page 80: ...DE 80 Version 2 0 KEN002PW18 25 11 2019...
Page 81: ...DE 81 Version 2 0 KEN002PW18 25 11 2019...
Page 118: ...FR 118 Version 2 0 KEN002PW18 25 11 2019...
Page 119: ...FR 119 Version 2 0 KEN002PW18 25 11 2019 D CLARATION DE PERFORMANCE ET RAPPORT D ESSAI...
Page 120: ...FR 120 Version 2 0 KEN002PW18 25 11 2019...