Version: 2.0
KEN002PW18 25.11.2019
[ EN
●
33 ]
When the stove is cold, remove the top, remove the
ceramics/ sides as described in section.3.3., loosening
the relative fastening screws before removing the
drivers 'B' and then remove the boiler cover 'C'. At this
point, remove the turbulators 'D' and using a rigid rod or
a bottle brush, clean the internal pipe unit and the tur
-
bulators, removing all of the accumulated ash. Check
the cover gasket and replace it if necessary.
ATTENTION:
It is advisable to carry out the cleaning
of the upper exchanger at the end of the season and
possibly by an authorized technician in order to replace
the gasket that is below plug 'C'.
CLEANING THE LOWER COMPARTMENT
Remove the ash drawer 'G', empty it and using the
nozzle of a vacuum cleaner remove any ash and soot
that may have built up under the drawer 'G'. Also remo
-
ve the grate 'F' and clean it every 2/3 days as explained
in chap. 5.1. Remove the drawer 'E', empty it and using
the nozzle of a vacuum cleaner remove any ash that
may have built up in the housing of the drawer 'E'.
ATTENTION:
It is advisable to carry out the cleaning
of the lower compartment 'E' once a week and in any
case according to the fuel consumption. Check the seal
of the ceramic fibre gaskets on the plug and replace
it if necessary. Check the seal of the door gasket and
replace it if necessary. At the end of the season it is
necessary to clean the compartment under the grate
and the heat exchanger inside it. This general cleaning
should be carried out at the end of the season in order
to facilitate the general removal of all residues of com-
bustion, without waiting too long, because with time
and humidity these residues can become compacted.
5.2.2
SHUTTING THE STOVE DOWN (END OF SEASON)
In the period when the stove is out of use it must be
disconnected from the electricity mains. For greater
safety, especially if there are children around, we
recommend removing the power cable from the rear of
the stove.
Before placing the stove in storage, you should remove
all pellets from the hopper with a vacuum cleaner with
a long extension.
CLEANING THE EXCHANGER AND PIPE UNIT (EGO/STAR)
CLEANING THE UPPER COMPARTMEN
Cleaning the pipe unit, tabulator and lower
compartment (EGO/STAR)
Disconnect the stove from the
electrical mains
Summary of Contents for PW18
Page 38: ...Version 2 0 KEN002PW18 25 11 2019 EN 38...
Page 39: ...Version 2 0 KEN002PW18 25 11 2019 EN 39 DECLARATION OF PERFORMANCE AND TEST REPORT...
Page 40: ...Version 2 0 KEN002PW18 25 11 2019 EN 40...
Page 41: ...Version 2 0 KEN002PW18 25 11 2019 EN 41...
Page 78: ...DE 78 Version 2 0 KEN002PW18 25 11 2019...
Page 79: ...DE 79 Version 2 0 KEN002PW18 25 11 2019 LEISTUNGSERKL RUNG UND PR FBERICHT...
Page 80: ...DE 80 Version 2 0 KEN002PW18 25 11 2019...
Page 81: ...DE 81 Version 2 0 KEN002PW18 25 11 2019...
Page 118: ...FR 118 Version 2 0 KEN002PW18 25 11 2019...
Page 119: ...FR 119 Version 2 0 KEN002PW18 25 11 2019 D CLARATION DE PERFORMANCE ET RAPPORT D ESSAI...
Page 120: ...FR 120 Version 2 0 KEN002PW18 25 11 2019...