If the fuel is left in the hopper, it may get damp, stick together, and be difficult to light at the beginning of the next season If
the stove is removed form its place of installation
it MUST be placed in a location that is protected from atmospheric
agents.
If pressing the main switch (located on the back of the stove) does not make the control panel display light up, it
could mean that the service fuse needs replacing
.
ATTENTION: Disconnect the electrical cable.
On the rear of the stove there is a fuse holding compartment which is located underneath the supply socket. With a
screwdriver open the cover of the fuse holding compartment, and replace the fuse if necessary (3.15 AT delayed type).
Plug the unit back in and press the main switch. If the problem persists or occurs again, contact service or your spezialized
technician
.
5.3 CHECK OF INTERNAL COMPONENTS
We recommend that an annual maintenance service is carried out, preferably under a programmed service contract. The
essential part of this service is a visual and functional check on the following components:
●
Reduction motor
●
Smoke expulsion fan
●
Smoke sensor
●
Heat-exchanger fan
●
Ignition sparkplug
● Resettable pellet thermostat
●
Room temperature sensor
● Motherboard / service card
● Fuses protecting panel - motherboard - services card
●
Wiring
The following is a summary of the checks and/or maintenance tasks which are indispensable for the correct operation of the stove
PARTS / INTERVAL
Every day
Every 2-3 days
Every 60-90 days
Every year
Grate
●
Ash drawer
●
Glass
●
Lower compartment
●
Complete exchanger
●
Smoke duct
●
Ash drawer door gasket
●
Internal parts
●
Flue pipe
●
Circulation pump
●
Plate heat exchanger
●
Plumbing components
●
Electro-mechanical components
●
IMPORTANT!
The check of the internal electromechanical components must be carried out only by qualified personnel
with technical knowledge of electricity and combustion.
Summary of Contents for PW18
Page 38: ...Version 2 0 KEN002PW18 25 11 2019 EN 38...
Page 39: ...Version 2 0 KEN002PW18 25 11 2019 EN 39 DECLARATION OF PERFORMANCE AND TEST REPORT...
Page 40: ...Version 2 0 KEN002PW18 25 11 2019 EN 40...
Page 41: ...Version 2 0 KEN002PW18 25 11 2019 EN 41...
Page 78: ...DE 78 Version 2 0 KEN002PW18 25 11 2019...
Page 79: ...DE 79 Version 2 0 KEN002PW18 25 11 2019 LEISTUNGSERKL RUNG UND PR FBERICHT...
Page 80: ...DE 80 Version 2 0 KEN002PW18 25 11 2019...
Page 81: ...DE 81 Version 2 0 KEN002PW18 25 11 2019...
Page 118: ...FR 118 Version 2 0 KEN002PW18 25 11 2019...
Page 119: ...FR 119 Version 2 0 KEN002PW18 25 11 2019 D CLARATION DE PERFORMANCE ET RAPPORT D ESSAI...
Page 120: ...FR 120 Version 2 0 KEN002PW18 25 11 2019...