PROBLEMS
REASON
SOLUTION
5. After ignition the power is off 15 min
later..
Pellet feeder unit is off or pellet is too
little.
30°C temperature switch breaks or the
connection wires of switch loose.
Not enough pressure in the stove.
Check the pellet feeder unit and
restart.
Check the connection wires or change
the 30°C temperature switch.
Adjust the combustion fan's speed up
6. Orange and lazy fire, piled pellet,
carbon on the glass
Lack of air intake for burning.
Clean the block in gate bar. Check the
door and window glass gasket sealed
or not. Check the air intake pipe and
venting pipe blocked or not, and
clean it. Change to the big diameter
pipes if pipes are too long to affect
combustion. Adjust the combustion
fan's speed up. Call the dealer to reset
the program
7. The fire put out and power is off
automatically.
The hopper is empty.
No fuel feed.
The fuel feed is too little.
Low temperature switch (30°C) is
wrong.
Set temperature is reached
Put fuel into the hopper. refer to (2)
Lower the speed of combustion fan
Cool the stove at least 1 hour then
operate again or change the low
temperature switch (30°C).
"ECO" its normal, waiting, after the
temperature is blow set on, it will
automatically switch on again
8. The blower still works after the stove
is cool and fuel feed stops.
The low temperature switch (30°C) is
broken.
Change this switch.
9. No enough heat wind
Unqualified fuel.
Blower speed is too high.
Heat exchange tubes are dirty.
Use the standard specially pellet
Use higher power
Clean the heat exchange tubes.
10. Showing "Pressure Error" on the
display
Vent pipe is blocked
The door is opening
The are some leakages
Shut down the stove, check the
venting pipe. Close the door and
unplugged then restart
Check it and repair it.
Adjust the combustion fan's speed up
to offer more pressure in the stove
NO increase in temperature with stove
in operation
1. Incorrect combustion adjustment
2. Boiler/system dirty
3. Insufficient stove power.
4. Poor pellet quality.
1. Check recipe and parameters.
2. Check and clean the boiler
3. Check that stove is properly sized
for the requirements of the system.
4. Use only permited fuels.
Condensation in boiler
1. Incorrect temperature setting.
2. Insufficient fuel consumption.
1. Set the stove to a higher tempe-
rature.
2. Check the recipe and/or technical
parameters
Summary of Contents for PW18
Page 38: ...Version 2 0 KEN002PW18 25 11 2019 EN 38...
Page 39: ...Version 2 0 KEN002PW18 25 11 2019 EN 39 DECLARATION OF PERFORMANCE AND TEST REPORT...
Page 40: ...Version 2 0 KEN002PW18 25 11 2019 EN 40...
Page 41: ...Version 2 0 KEN002PW18 25 11 2019 EN 41...
Page 78: ...DE 78 Version 2 0 KEN002PW18 25 11 2019...
Page 79: ...DE 79 Version 2 0 KEN002PW18 25 11 2019 LEISTUNGSERKL RUNG UND PR FBERICHT...
Page 80: ...DE 80 Version 2 0 KEN002PW18 25 11 2019...
Page 81: ...DE 81 Version 2 0 KEN002PW18 25 11 2019...
Page 118: ...FR 118 Version 2 0 KEN002PW18 25 11 2019...
Page 119: ...FR 119 Version 2 0 KEN002PW18 25 11 2019 D CLARATION DE PERFORMANCE ET RAPPORT D ESSAI...
Page 120: ...FR 120 Version 2 0 KEN002PW18 25 11 2019...