PROBLEMS
REASON
SOLUTION
Radiators cold in winter
1. room thermostat (local or remote)
set too low if remote thermostat, check
if it is defective.
2. circulator does not run because
blocked.
3. Circulator does not run.
4. Radiator have air in them
1. Set to higher temperature or
replace ( if remote).
2. Free up the circulator by removing
the plug and turning the shaft with
screwdriver.
3. Check the electrical connections of
the circulator; replace if necessary
4. Vent the radiators
Hot water is not provided
Circulator (pump) blocked
Free the circulator (pump)
ELECTRICAL GENERATOR OPERATION
Your stove can be powered with a gas driven electrical generator.
However, the generator's electrical regulator may not be compatible with the stove's electronics. The higher the quality of
the generator, the greater the chance that it is compatible with the stove
7. ELECTRICAL DIAGRAM
Summary of Contents for PW18
Page 38: ...Version 2 0 KEN002PW18 25 11 2019 EN 38...
Page 39: ...Version 2 0 KEN002PW18 25 11 2019 EN 39 DECLARATION OF PERFORMANCE AND TEST REPORT...
Page 40: ...Version 2 0 KEN002PW18 25 11 2019 EN 40...
Page 41: ...Version 2 0 KEN002PW18 25 11 2019 EN 41...
Page 78: ...DE 78 Version 2 0 KEN002PW18 25 11 2019...
Page 79: ...DE 79 Version 2 0 KEN002PW18 25 11 2019 LEISTUNGSERKL RUNG UND PR FBERICHT...
Page 80: ...DE 80 Version 2 0 KEN002PW18 25 11 2019...
Page 81: ...DE 81 Version 2 0 KEN002PW18 25 11 2019...
Page 118: ...FR 118 Version 2 0 KEN002PW18 25 11 2019...
Page 119: ...FR 119 Version 2 0 KEN002PW18 25 11 2019 D CLARATION DE PERFORMANCE ET RAPPORT D ESSAI...
Page 120: ...FR 120 Version 2 0 KEN002PW18 25 11 2019...