Version: 2.0
KEN002PW18 25.11.2019
[ EN
●
8 ]
no fire hazard such as: garages, sheds, storage of combustible materials, etc., strictly complying with the
requirements under current rules. It is absolutely prohibited to installation the stove in bedrooms, bathrooms,
and where it is already installed another d heating device without adequate airflow (fireplace, stove, etc.).
It is expressly prohibited the placement of the stove in
environments with explosive atmospheres. The floor of
the room where the stove will be installed must be sized
appropriately to support the weight of the stove itself (which
should be considered in addition to the weight of the machine
said the same load must be added a maximum of 60 kg for the
pellets, and 80 kg for water). When installing, keep a minimum
distance from obstacles and not flammable (B) of 20 cm the rear
to, lateral (LR) of 20 cm and anterior (C) of 80 cm. In the presence
of objects believed to be particularly sensitive such as furniture,
curtains, sofas, carpets, etc., greatly increase the distance of the
stove from them. In the presence of wooden floor floor-prepare
the plan and in accordance with rules in force in the country, on
fire prevention.
A
B
2.4 CONNECTION TO THE EXTERNAL AIR INTAKE
It is essential that the room where the stove is installed, the stove can
avail of an air flow in sufficient quantity as it is required by the regular
combustion equipment and ventilation. This can be done by means of
permanent openings on the walls that give the room to be ventilated to
the outside, ventilation ducts or through individual or collective. Within
this scope, the outer wall near the stove must have an opening minimum
100 cm
2
, protected by a grid inside and outside.
The air intake must also:
● be communicating directly with the installation environment
● be protected by a grate, wire mesh or other suitable protection, provided it does not reduce the minimum section.
● position in a suitable manner as to prevent it from being obstructed in any way
It is prohibited to connect the air directly to the stove (communicating directly from the out-
side), to avoid compromising thermodynamic performance, however it is required that the
conditions still guarantee about 50 m
3
/h of air replacement, as provided in the current UNI
10683
.
Summary of Contents for PW18
Page 38: ...Version 2 0 KEN002PW18 25 11 2019 EN 38...
Page 39: ...Version 2 0 KEN002PW18 25 11 2019 EN 39 DECLARATION OF PERFORMANCE AND TEST REPORT...
Page 40: ...Version 2 0 KEN002PW18 25 11 2019 EN 40...
Page 41: ...Version 2 0 KEN002PW18 25 11 2019 EN 41...
Page 78: ...DE 78 Version 2 0 KEN002PW18 25 11 2019...
Page 79: ...DE 79 Version 2 0 KEN002PW18 25 11 2019 LEISTUNGSERKL RUNG UND PR FBERICHT...
Page 80: ...DE 80 Version 2 0 KEN002PW18 25 11 2019...
Page 81: ...DE 81 Version 2 0 KEN002PW18 25 11 2019...
Page 118: ...FR 118 Version 2 0 KEN002PW18 25 11 2019...
Page 119: ...FR 119 Version 2 0 KEN002PW18 25 11 2019 D CLARATION DE PERFORMANCE ET RAPPORT D ESSAI...
Page 120: ...FR 120 Version 2 0 KEN002PW18 25 11 2019...