background image

 

 

     

         NEMCO FOOD EQUIPMENT   

301 Meuse Argonne, Hicksville, OH 43526     

                                   1-800-782-6761 Toll Free   419-542-6690 Fax

                                          

 

                                                     www.nemcofoodequip.com                                                                       49206 

 

 
 
 

 

INSTALLATION INSTRUCTIONS 

 

IMPORTANT:

 The 3 Shelf Humidified Merchandiser must be installed on a clean, flat surface capable of supporting 

the merchandiser.  The approximate weight of the merchandiser is 205 pounds when completely filled with water. 
 

IMPORTANT:

 The 3 Shelf Humidified Merchandiser 

MUST BE

 used with 

4” leg or sealed directly to countertop using 

the supplied gasket and/or an NSF 51 listed silicone to countertop as required by local Health Department. The 
merchandiser 

MUST BE 

sealed to the surface using an NSF 51 listed silicone if food product is being prepped on the 

same surface as the merchandiser is installed onto.  
 

IMPORTANT:

 

When the merchandiser is turned on for the first time, allow the unit to run for approximately an hour to 

allow the elements to burn off. If the unit is plugged into a GFCI, it may reset the GFCI during this time.  
 

1.  Remove all the packaging from the exterior of the merchandiser. 
2.  Set the merchandiser on a clean, flat surface capable of properly supporting the merchandiser weight. IMPORTANT: 

Do not slide the merchandiser as it may damage the gasket.   

3.  Remove the fluorescent light bulb from the box and install into the top of the unit. 
4.  Remove the racks from the box and place into the unit as marked on the packaging. NOTE: The dip in the front of the 

top two racks is to be located at the front of the merchandiser.  

5. 

Install the drain tube kit onto the rear drain tube on the back of the merchandiser using a ¾” wrench. (Figure #1) 
Note: All male threads will need thread tape applied to seal the connection.  

6.  Install the drain tube holder by removing the (2) Phillips head screws mounting the rear sign bracket in place above 

the drain (Figure #2 

– A). Place the drain tube holder between the rear sign bracket and the rear panel align the 

holes in the tube holder and the sign bracket (Figure #2 

– B). Re-install the (2) Phillips head screw back into the 

original holes (Figure #2 

– A).   

7.  Clean thoroughly using a mild detergent and warm water before first use.  
8.  Plug the merchandiser into a certified electrical outlet with a corresponding voltage rating as listed on the Data Tag 

and turn the merchandiser on.  

9.  Fill the merchandiser with approximately 2-1/2 gallons (10 quarts) of water until the green fill light turns on.  

10.  Allow the merchandiser to preheat and run for approximately one hour to allow the elements to burn off prior to first use. 

NOTE: 

If the unit is 

plugged into a GFCI outlet, it may reset the GFCI during this time.  

11.  If unit fails to work properly when first operated, call NEMCO customer service at 1-800-782-6761. 

 
 
 

  
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 


 


 


 

FIGURE #1 
 

FIGURE #2 
 

Summary of Contents for 6470

Page 1: ......

Page 2: ...ment s Data Tag Located on the rear panel of the merchandiser 2 CAUTION This unit s power cord is equipped with a GROUNDED 3 prong power cord Plug only into a matching grounded outlet DO NOT cut or break off the third prong Operating this equipment without proper grounding may result in electric shock 3 CAUTION Always disconnect Power when not in use and before cleaning or servicing 4 CAUTION Do n...

Page 3: ...bulb from the box and install into the top of the unit 4 Remove the racks from the box and place into the unit as marked on the packaging NOTE The dip in the front of the top two racks is to be located at the front of the merchandiser 5 Install the drain tube kit onto the rear drain tube on the back of the merchandiser using a wrench Figure 1 Note All male threads will need thread tape applied to ...

Page 4: ...erature to the desired temperature To advance to the next setting and save the new air temperature setting press the SETTINGS button 3 The next setting is the humidity setting and the water level LED will now begin to blink 4 Press the UP or DOWN adjust the humidity power to the desired power setting 5 Press the SETTINGS button once more to exit the settings menu and save the program CLEANING IMPO...

Page 5: ... the Shoulder Bolt from the left side of the door using a 2 Phillips Head Screwdriver With the Shoulder Bolt removed pivot the door outward and remove the door from the dampener on the right side Place the shoulder bolt washer and door aside Repeat for the process for the next 2 doors 3 Replace the 3 dampeners by sliding them out of the mount and discard the old dampeners Insert new dampeners in p...

Page 6: ...Meuse Argonne Hicksville OH 43526 1 800 782 6761 Toll Free 419 542 6690 Fax www nemcofoodequip com 49206 6 Upper Deck Section View Indicates location of hose clamp Air Flow Flips Up Flips Down Flips Down Lower Deck Section View ...

Page 7: ... into the cabinet 10 47397 1 Fan Water Tank Water Tank Housing Assembly 0 18A 115VAC Verify air flow Install with the air flowing across the water tank 11 48703 Control Board Control Panel N A Verify the control board is properly controlling the setting by adjusting the setting 12 48704 Sensor RH Temp Left Upright N A Control board will display Err1 Check connection between sensor and board prior ...

Page 8: ...EQUIPMENT 301 Meuse Argonne Hicksville OH 43526 1 800 782 6761 Toll Free 419 542 6690 Fax www nemcofoodequip com 49206 8 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 Component Parts Images ...

Reviews: