Plumber or equivalent trade skill required for proper install
1.
Disconnect drain from old well and water supply from old faucet.
2.
Install new well, install drain cup.
3.
Install faucet box.
4.
Install control box below the well. Top of box must be minimum
12 in. below the drain connection. (3 ft. of hose is provided.)
5.
Install cold fresh water connection to control box.
6.
Install hoses and communication cable.
7.
Connect power supply to control box.
(Power supply cord length 6ft.)
8.
Follow initial startup procedure.
1. Install per Instructions above
2. System Startup
STEP 1.
Insert overflow stand tube.
STEP 2.
Press contol button to turn on, control button should
blink rapidly and water will begin to fill the well.
3. Fill Level Calibration
When water begins to drain down stand tube,
press the control button once. This will set the fill level.
RinseWell
®
Smart Eco Rinse
Control button
Overflow stand tube
Installation Overview
Initial Startup Quick Guide
Run Mode
Press control button 1 time to enable run mode.
Control button will be solid blue light.
Manual Clean
If during normal use the water is not clear or has some foaming,
press the control button 1 time to enable a manual clean cycle.
End of day mode consists of a 3 minute flush followed by a continuous
recirculation of water until the control button is pressed to enable run mode
STEP 1.
Press control button 3 times to enable end of day.
Control button will blink slowly.
STEP 2.
While unit is flushing, remove shroud, stand tube and screen. Clean vessel and
all parts. Stand tube should be re-installed within 2 minutes of step 1.
STEP 3.
Install shroud, stand tube and screen. Make sure water level is to top of stand
tube. (Repeat step 1 if water is not at top of stand tube)
•
Control button will continue to slowly blink indicating end of day mode.
•
Follow run mode instructions when ready to use the unit.
Control Button
Blue Light Reference
Steady Light : Run Mode
Slow Blink : End Of Day Mode
Slow Pulse : Standby (Off)
Fast Pulse : Fill Calibration
ERROR INDICATORS:
2 Pulses : Pump Failure
3 Pulses : Fan Failure
Shroud
Stand tube and screen
Quick Reference
Run Mode/Manual Clean
End Of Day