background image

Plumber or equivalent trade skill required for proper install

1. 

Disconnect drain from old well and water supply from old faucet.

2.

 Install new well, install drain cup.

3.

 Install faucet box.

4.

  Install control box below the well. Top of box must be minimum  

12 in. below the drain connection. (3 ft. of hose is provided.)

5.

 Install cold fresh water connection to control box.

6.

 Install hoses and communication cable.

7. 

 Connect power supply to control box.  
(Power supply cord length 6ft.)

8.

 Follow initial startup procedure.

1. Install per Instructions above
2.     System  Startup

 

 

STEP 1.

 Insert overflow stand tube.

     STEP 2.

  Press contol button to turn on, control button should 

blink rapidly and water will begin to fill the well. 

3.  Fill Level Calibration

 

When water begins to drain down stand tube,  
press the control button once. This will set the fill level.

RinseWell

®

 

Smart Eco Rinse

Control button

Overflow stand tube

Installation Overview

Initial Startup Quick Guide

Run Mode

Press control button 1 time to enable run mode.   
Control button will be solid blue light.

Manual Clean

If during normal use the water is not clear or has some foaming,  
press the control button 1 time to enable a manual clean cycle.

End of day mode consists of a 3 minute flush followed by a continuous 

recirculation of water until the control button is pressed to enable run mode

STEP 1.

  Press control button 3 times to enable end of day.  

Control button will blink slowly.

STEP 2.

  While unit is flushing, remove shroud, stand tube and screen. Clean vessel and 

all parts. Stand tube should be re-installed within 2 minutes of step 1.

STEP 3.

  Install shroud, stand tube and screen. Make sure water level is to top of stand 

tube. (Repeat step 1 if water is not at top of stand tube)

 

 Control button will continue to slowly blink indicating end of day mode.

 

 Follow run mode instructions when ready to use the unit. 

Control Button  

Blue Light Reference

Steady Light : Run Mode
Slow Blink : End Of Day Mode
Slow Pulse : Standby (Off)
Fast Pulse : Fill Calibration

ERROR INDICATORS:
2 Pulses : Pump Failure
3 Pulses : Fan Failure