5. The operation completes when the hydraulic pressure
reaches 700 bar ot 1 0,000psi and the safety relief valve
is activated.
6. Press the release button to retract the piston.
7. Repeat steps 5-7 to perform the remaining according to your requirement.
8. Cleaning the tool before storing in the case. Always store the tool in its case
with the cylinder piston fully retracted.
TTENTION!
Do not put your fingers through the crimping area of the crimper to
remove the cable when the battery pack is in place and you are holding the
tool with you other hand. Pay attention! The piston and indenters
advance quickly. lf the trigger is accidentally pressed, it can result in
severe damage to your hand. For your safety, remove the battery pack
whenever the tool is sitting idly. Do not use this tool when you are tired or
distracted. Keep away from children.
11