54
controlled blast chilling cycle has been completed
if this LED is flashing, a timer controlled blast chilling and storage cycle
has been selected.
LED temperature controlled blast chilling
• if this LED is on and LED is off, a temperature controlled blast
chilling cycle is running
• if this LED is on and LED is on, storage is running after a temperature
controlled blast chilling cycle has been completed
if this LED is flashing, a temperature controlled blast chilling and storage
cycle has been selected.
if this LED comes on for ½ a second every 3 seconds, a needle probe
test is being run
• if this LED is flashing and LED
is on, needle probe testing results
negative (parameters rc and rd) the cycle switches to timer controlled
blast chilling; refer to paragraph 3.6
• if this LED is flashing and is on, chilling has not been completed and
blast chilling will continue.
• if this LED is flashing and LEDs and are on, blast chilling has not
been completed but the system is now in storage mode
LED storage
if on, the chiller is in storage mode
if this LED is flashing, the working setpoint is being modified during
storage (refer to paragraph 4.1)
°C
LED alarms
if on, an alarm has been activated
LED degree Celsius
if on, the unit of measurement is in degrees Celsius (parameter P2)
°F
LED degrees Fahrenheit
if on, the unit of measurement is in degrees Fahrenheit (parameter P2)
Decimal
point
point
LED minute
if flashing, the unit of measure displayed is in
minutes
CODE
MEANING
- d -
- d -
defrosting or dewatering is running
6
Alarms
6.1
Alarm prompts