type of maximum temperature
alarm
0 = no alarm
1 = refers to parameters r9 and
rA (namely “r9 + A4” and “rA +
A4”)
A6
0
240
min
15
delay in temperature alarm from
when chiller goes into storage
mode
A7
0
240
min
15
temperature alarm delay
A8
0
240
min
15
delay in maximum temperature
alarm
after
dewatering
has
terminated (6)
A9
0
240
min
15
delay in maximum temperature
alarm from when the microport
input is disabled (only if i0=0
or 1) (7)
AA
0
240
s
5
buzzer
duration
time
when
chilling has been completed
PARA
M
MIN.
MAX
.
U.M.
DEF.
EVAPORATOR FAN only if U0
= 1
F0
0
2
---
2
evaporator fan during blast chilling
0 = off
1 = on
2 = in parallel with compressor
F2
0
2
---
1
evaporator fan during storage
0 = off
1 = on
F8
0
99
min
0
delay in evaporator fan during
defrosting from when one of the
following digital input functions
PARAM MIN.
MAX. U.M.
DEF.
DIGITAL INPUTS
i0
0
2
---
1
is enabled
0 = INPUT MICROPORT – in
this case parameters i1, i2 and i3
are active; when the input is