Installer Options
SIREN-OFF TIME
The time for the siren to be silent after the Siren-On Time has elapsed, can be changed by
pressing the
0
key followed by the
2
key. Select the desired time from the table and press
the corresponding number from
0
to
4
followed by the
#
key. The keypad will beep twice to
indicate that the new setting was accepted.
Example: To change the Siren-Off Time to 2 minutes,
enter
0 2 3 #
The default Siren-Off Time is
4 minutes
.
NUMBER OF TIMES THE SIREN SOUNDS
The number of times the siren will sound after an alarm is activated, can be changed by
pressing the
0
key, followed by the
3
key. Select the desired number of times from the table
and press the corresponding number from
0
to
4
followed by the
#
key. The keypad will
beep twice to indicate that the new setting was accepted.
Example: To change the Number of Times The Siren
Sounds to 10 times, enter
0 3 4 #
The default Number of Times The Siren Sounds is
3 times
.
GATE DELAY TIME
The time delay for the gate to stay open before the alarm is activated, can be changed by
pressing the 0 key, followed by the 4 key. Select the desired time delay from the table and
press the corresponding number from 0 to 4 followed by the # key. The keypad will beep
twice to indicate that the new setting was accepted.
Example: To change the Gate Delay Time to 30 seconds,
enter 0 4 1 #
The default Gate Delay Time is
4 minutes
.
HIGH POWER FENCE VOLTAGE
The open circuit fence voltage can be changed by pressing the
0
key, followed by the
5
key.
Select the desired voltage from the table and press the corresponding number from
0
to
4
followed by the
#
key.
0
10 Sec
1
30 Sec
2
1 Min
3
2 Min
4
4 Min
0
Once
1
Twice
2
3 Times
3
6 Times
4
10 Times
0
15 Sec
1
30 Sec
2
1 Min
3
2 Min
4
4 Min
2
0
#
3
0
#
4
0
#
5
0
#