background image

WARRANTY INFORMATION

Acorn warrants that all of its products are guaranteed against defective material or poor workmanship for a period of 
one year from date of shipment. Acorn's liability under this warranty shall be discharged by replacing without charge 
F.O.B. City of Industry, California, any goods, or part thereof, which appears to the company upon inspection to be of 
defective  material  or  not  of  first  class  workmanship,  provided  that  claim  is  made  in  writing  to  the  company  within 
reasonable period after receipt of the product. Where claims for defects are made, the defective part or parts shall be 
delivered to the company, prepaid, at City of Industry, California for inspection. Acorn will not be liable for the cost of 
repairs, alterations or replacement, or for any expense connected therewith made by the owner or his agents, except 
upon  written  authority  from  the  Acorn  City  of  Industry  office.  Acorn  will  not  be  liable  for  any  damages  caused  by 
defective  materials  or  poor  workmanship,  except  for  replacements,  as  above  provided.  Contact  local  Acorn 
Representative for complete terms and conditions.

M A I L  A D D R E S S 

P. O .  B O X  3 5 2 7  

C I T Y  O F  I N D U S T R Y,  C A  9 1 7 4 4  U . S . A .

P H Y S I C A L  A D D R E S S 

1 5 1 2 5  P R O C T O R  AV E N U E  

C I T Y  O F  I N D U S T R Y,  C A  9 1 7 4 6  U . S . A .

T O L L  F R E E

  8 0 0 - 4 8 8 - 8 9 9 9  • 

L O C A

L  6 2 6 - 3 3 6 - 4 5 6 1

FA X

  6 2 6 - 9 6 1 - 2 2 0 0  • 

W E B

  w w w. a c o r n e n g . c o m 

Date: 07/30/18

Page 14 of 14

Part #: 3050-003-001

 NEO-METRO FIELD SERVICE

TOLL FREE

 800-743-8259 • 

LOCAL

  626-855-4866 • 

FAX

 626-855-4863

INSTALLATION, OPERATIONS 

& MAINTENANCE MANUAL

Please visit 

 

for most current specifications.

www.neo-metro.com

Summary of Contents for 9121

Page 1: ... Line Hammer 7 16 Hex Wrench 3 8 12 Count Fixture Wall Anchors and Anchoring Hardware and Appropriate Tools Teflon Tape 10 10 Count Fixture Wall Anchors and Anchoring Hardware and Appropriate Tools Please visit www neo metro com for most current specifications INSTALLATION OPERATIONS MAINTENANCE MANUAL NEO METRO A Member of Morris Group International Morris Group 15125 Proctor Avenue City of Indus...

Page 2: ... assembly must be drained prior to being subjected to freezing temperatures The valve assembly has a check integral to the inlet however angle stop is to be provided by the installer Provide 110 120 VAC 60Hz 15A dedicated circuit when Dyson Airblade Faucet selected Refer to Dyson installation instructions for more information Important Some options may slightly alter installation To ensure proper ...

Page 3: ...743 8259 LOCAL 626 855 4866 FAX 626 855 4863 PAT BASIN 9121 9141 ACCESSIBILITY COMPARISONS ADA OBC Date 07 30 18 Page 3 of 14 Part 3050 003 001 21 1 2 34 RIM MAX ADA PROFILE 11 1 4 22 3 4 11 1 4 3 3 4 27 31 3 4 AFF 21 1 2 33 RIM MAX 11 1 4 22 3 4 10 1 4 3 3 4 OBC PROFILE 30 3 4 AFF ...

Page 4: ...L NEO METRO FIELD SERVICE TOLL FREE 800 743 8259 LOCAL 626 855 4866 FAX 626 855 4863 DIMENSIONAL DATA Date 07 30 18 Page 4 of 14 PAT BASIN 9121 9141 Part 3050 003 001 MODEL 9121 MODEL 9141 8 21 1 2 3 3 4 22 3 4 8 21 1 2 3 3 4 22 3 4 26 2 26 2 ...

Page 5: ...upply Inlets C Wall Anchoring for 9 16 Diameter Mounting Bracket Holes 2 Places D 120VAC 60 Hz 3A Max Electric Hard wire E Optional Wall Anchoring for 219 Diameter x 5 8 Long Enclosure Mounting Slots 4 Places 18 8 3 5 34 AFF 2 5 91 2 25 AFF 21 34 AFF 321 2 AFF 301 2 AFF A Waste Outlet for 1 1 2 O D P Trap Provided E E E E C C A B D MOUNTING PLUMBING Date 07 30 18 Page 5 of 14 PAT BASIN 9121 9141 P...

Page 6: ...ly Inlets C Wall Anchoring for 9 16 Diameter Mounting Bracket Holes 2 Places D 120VAC 60 Hz 3A Max Electric Hard wire E Optional Wall Anchoring for 219 Diameter x 5 8 Long Enclosure Mounting Slots 4 Places 18 8 3 5 33 AFF 2 5 91 2 24 AFF 21 33 AFF 311 2 AFF 291 2 AFF A Waste Outlet for 1 1 2 O D P Trap Provided E E E E C C A B D MOUNTING PLUMBING Date 07 30 18 Page 6 of 14 PAT BASIN 9121 9141 Part...

Page 7: ...OTE It may be advantageous to install to the deck faucets soap dispensers or other accessories prior to wall mounting FYI Fixtures are shipped with wall mounting brackets pre installed onto the fixture IMPORTANT are intended to meet ADA Guidelines Straight or requirement portions of fixture 1 refers to the stations that Level lavatory 3 using front 4 and back 5 leveling screws Date 07 30 18 Page 7...

Page 8: ...ket Ä 1 1 2 16 x 1 1 4 UNI Close Elbow with 3 8 NPT Clean Out Plug  Flat Fiber Washer À Grid Strainer w 1 1 2 16 UNE Threads à 1 1 2 16 UNI Rough Chrome Brass Jam Nut Install grid strainer and close elbow to bowl using plumber s putty A Assemble waste piping using teflon tape on all threaded connections and make up waste connections to 1 1 2 P Trap B 11 4 81 4 5 Date 07 30 18 Page 8 of 14 PAT BAS...

Page 9: ...using 1 2 NPT connections provided 4 Turn on hot and cold water supplies If any leaks are observed hand tighten connections as necessary to stop leaks before proceeding 3 Turn temperature stem counter clockwise for hotter or clockwise for colder outlet temperature 4 Tighten locknut to prevent accidental or unauthorized temperature adjustment 1 Loosen locknut 5 Re check outlet temperature 2 Turn on...

Page 10: ...es prior to wall mounting All wall anchors and anchoring hardware provided by others TRAP ENCLOSURE INSTALLATION Position station enclosures 1 aligning mounting points 2 and secure with installer provided hardware Optional MXTP Valve Shown For Reference Angle Stops and Flex Hoses Provided By Others PAT Basin Model 9121 Shown For Reference Front View 1 2 2 2 2 Date 07 30 18 Page 10 of 14 PAT BASIN ...

Page 11: ...mer resin aluminum trihydrate and fillers It is resistant to stains impact and burns and complies with ANSI Z124 3 It is attractive durable and easy to maintain REPAIRING SURFACE DAMAGE Surface damage such as minor chips scratches burn marks and graffiti can be repaired with a fine grit abrasive cleanser such as a Scotch Brite pad or fine grit sandpaper For more serious physical damage caused by v...

Page 12: ...r Washer COMPONENTS REPAIR PARTS Description Part No Diagram 0337 050 000 1 4 Stainless Steel Helical Lock Washer Dyson Airblade Wash Dry Short Deck Mounted Faucet 3040 091 000 ST70 12 1 2 NPT Mixing Valve ST70 12 Valve Bracket Assembly 7802 101 001 7842 020 001 MOUNTING HARDWARE SPOUTS VALVE Dyson Airblade Wash Dry Wall Wall Mounted Faucet 3040 093 000 Date 07 30 18 Page 12 of 14 PAT BASIN 9121 9...

Page 13: ...26 855 4863 COMPONENTS REPAIR PARTS Description Part No Diagram WASTE ASSEMBLY Grid Strainer w Close Elbow 4926 062 001 P Trap Waste Assembly 4970 040 003 ENCLOSURES Trap Enclosure Assembly 9121 3050 010 001 Date 07 30 18 Page 13 of 14 PAT BASIN 9121 9141 Part 3050 003 001 Trap Enclosure Assembly 9141 3050 210 001 ...

Page 14: ...inspection Acorn will not be liable for the cost of repairs alterations or replacement or for any expense connected therewith made by the owner or his agents except upon written authority from the Acorn City of Industry office Acorn will not be liable for any damages caused by defective materials or poor workmanship except for replacements as above provided Contact local Acorn Representative for c...

Reviews: