Location and Installation of the Drain Saddle

 

Here are a few tips to use when deciding the location and installing:

 

• 

Place the drain saddle as far away from a disposal as possible.

 

A disposal can shoot debris into the drain 

line and block the air gap. Locate a place where tubing can run as straight as possible without looping or 

extreme bending.

 

• 

Adjust excess tubing

 

that dips below the saddle location that

 

causes water to back up the air gap and leak 

out.

 

• 

Keep the drain saddle from rotating away from the drilled hole.

 

Here's how: apply the clamp, tighten it, 

then drill the hole. Be careful not to damage the tube connection fitting. Rotation can also occur over time 

if your system under the sink gets bumped.

  

• 

Use a horizontal mount

 

to minimize the gurgling noise your RO system makes while filtering water. The 

location of the saddle drain

 

may also help.

  

• 

Never position on the wall side of the P

-

Trap.  

The P

-

Trap is there to keep sewer gas from coming out your 

sink drain.  Placing the saddle on the back side of the p

-

trap will allow the sewer gas to come out the airgap 

hole!

 

 

Clear accumulated debris

 

by taking the tubing apart from the saddle. During the cleaning process, make sure 

the hole is properly lined up with the clamp. Insert a pencil or small screwdriver through the fitting to ensure 
proper alignment.

 

 

Summary of Contents for PRO-41000-A Series

Page 1: ...Installation Guide 6 29 2023 1 The High Efficiency Reverse Osmosis Drinking Water System Installation Operation and Service Manual PRO 41000 A Series...

Page 2: ...embly Installation 7 Component Location Diagram 8 System Component and Replacements 9 Drain Saddle Location Description 10 Drain Saddle and Feed Supply Installation 11 Airgap Faucet Installation 12 Fi...

Page 3: ...ke sure you understand the location and installation requirements of the air gap faucet that came with the system Water Quality In order for the system to function properly it is important to make sur...

Page 4: ...membrane is a specially constructed fully aromatic polyamide film and is classified as a Thin Film Composite TFC The spiral wound construction of the RO Membrane provides maximum surface area for wate...

Page 5: ...ate Pump Auto Shut Off Flow Restrictor Installation Kit Components Tubing for connection to water supply tank faucet and drain Feed supply adapter Drain saddle clamp Stem adapter and elbow fitting for...

Page 6: ...the cap from the housing 2 Insert the membrane o ring end first with the brine seal on the cap end Push it in all the way 3 Replace the housing cap and reconnect the feed supply tubing Each membrane o...

Page 7: ...connect to the PERMEATE IN port 4 Locate the red tubing hanging between the two housings that is connected to the membrane housing and flow restrictor This connects to the BRINE IN port Once the air g...

Page 8: ...cet prior to installing it Then feed the tubes down through the installation hole for the faucet Finish the faucet mount and connect the tubing to the following 1 1 4 Red tube goes on the small barb o...

Page 9: ...D Membrane FR 650 JG Flow Restrictor 75 Feed water To Faucet To Tank To Airgap Remineralizer Membrane Post Filter Pre Filter Permeate Pump Auto Shut Off Flow Restrictor To Remote Hook up Ice maker or...

Page 10: ...he clamp tighten it then drill the hole Be careful not to damage the tube connection fitting Rotation can also occur over time if your system under the sink gets bumped Use a horizontal mount to minim...

Page 11: ...d to fit 3 8 compression supply threads and has adapters for 1 2 NPS connections 1 Locate the cold water supply valve shut off under the sink Turn off the cold water supply 2 Turn on the kitchen fauce...

Page 12: ...t ribs support brackets or other under sink construction CAUTION To prevent eye injury safety glasses must be worn during sink drilling operation Review components shown in Air Gap Faucet diagram Figu...

Page 13: ...ure the tubing is pushed all the way in If uncertain measure 3 4 and mark the end of the tube It is pushed in all the way if the line disappears into the fitting If tubing is in far enough and still l...

Page 14: ...ay intermittently spurt from the air gap opening on the side of air gap faucets This is common and should correct itself after the air is purged from the system CAUTION Ensure that the system is not b...

Page 15: ...cated in the top of the filter housing and lubricated with silicon based lube 8 Insert the new Filter into the housing and rotate the housing back on to the cap clockwise Be careful to allow the top o...

Page 16: ...o fill Most systems will be full within 2 3 hours depending on feed pressure membrane output and tank size The system is full when the water to the drain stops Check for leaks with the system full and...

Page 17: ...4 from the non valved insert 2 Shake as much water as you can from the tube 3 Fill the syringe with the liquid sanitizer and empty it into the coupling body 4 so that it enters the tank through the tu...

Page 18: ...water is out adjust the empty tank air pressure to 5 7 psi Reinstall the tank under the sink and turn feedwater back on an allow the tank to fill Carbon post filter is clogged Replace filter Tank val...

Page 19: ...n any defective component You must pay any labor charges You must also pay for shipping or travel charges to return the defective part s What Does This Warranty Not Cover This warranty does not cover...

Page 20: ...Installation Guide 6 29 2023 20...

Reviews: