Chapter 8: Specifications
HHP 5000 Imager Performance
236
NEO Hand-Held with Windows Mobile 6.1 Classic User Manual
8.3.3.1 HHP 5000 Decode Zone
Performance Focal Point
Size
1.78 cm Depth x 2.79 cm Width (without mounting tabs) x 1.21
cm Height
0.7 in. Depth x 1.1 in. Width (without mounting tabs) x 0.475 in.
Height
Weight
5.9 grams (.21 ounces)
Operational Input Voltage
Imager: 3.3 VDC ±5% (23°C)
Illumi Aimer 5300: 3.0 VDC to 5.5 VDC (23°C)
Operating Temperature
-30° to +50°C (-34° to 122°F)
Storage Temperature
-40° to +70°C (-40° to 158°F)
Humidity
up to 95% RH, non-condensing at 122° F (50°C)
Shock
18 shocks of 3,500 G for 0.5 msec at 23°C (73° F)
SR
7 inches (17.8 cm) from lens plate
SR Working
Range
8.3 mil
Linear
(.02 cm)
10 mil
PDF417
(.025 cm)
13 mil UPC
(.033 cm)
15 mil Data
Matrix
(.038 cm)
15 mil QR
(.038 cm)
35 mil Maxi-
code
(.089 cm)
Near
3.5 in.
(8.9 cm)
3.1 in.
(7.9 cm)
2.1 in.
(5.3cm)
2.3 in.
(5.8 cm)
2.1 in.
(7.9 cm)
2.0 in.
(5.1 cm)
Far
7.6 in.
(19.3cm)
9 in.
(22.9 cm)
13.2 in.
(33.5 cm)
10.2 in.
(25.9 cm)
8.8 in.
(22.4 cm)
13.0 in.
(33 cm)