4.4 Component list setting
Function: display the information and mounting order of components. The components’ quantity and mounting information
can be added through manual programming or importing files , see below figure:
4.4.1 Manual programming
(1) Select manual programming;
(2) Edit the first component: there will be an example component in the component information list, modify the sample
component and click position “align”, the page will switch to the vision of up-looking camera automatically. Move the
camera and find the first component’s center coordinate. Click save.
(3) Fill in the information of component: Stack refers to which stack No. the component located; Nozzle refers to which
nozzle used to mounting the component; Specification refers to the component’s value; Footprint refers to the common
footprint name as 0402,0603,0805 etc; XY coordinate refers to the position of where the component is mounted, align the
center position of component, it will display synchronously; The angle is based on the placement direction of components
on the circuit board. Transverse is 0 degree or 180 degree, vertical is 90 degree or negative 90 degree, which mainly
depends on the polarity of component, degree must be integer degree; Skip setting includes true or false, false means keep
mounting, true means skip mounting this component. After finish all parameters’ editing, the setting of first component
information finish.
(4) Click ‘New’ to add one row on the component list. The information will exactly copy from the top row. Click align to
find the second component’s coordinate. Then click save to edit the other information such as name, value, footprint and
angle etc. Keep adding new component until the whole PCB finish. Please note the the stack and nozzle do not need to be
edited manually. It can be set through feeder setting interface with ‘Assign all sequentially’ button to assign the information