1.  Immobilize the bull

 

Use a head gate and squeeze chute, or similar solid enclosure, to limit the side-to-side 
and forward and backward motion of the bull. Bulls with room to move are more likely 
to fall, making collections more difficult.

2.  Footing is critical

 

Providing secure footing is perhaps the most important aspect of preparing a bull for 
collection. Bulls that are slipping and sliding are difficult to collect from. Some veteri-
narians spread a bucket of sand over the enclosure’s floor to increase a bull’s footing, 
and others have bulls stand in ankle-deep sand to ensure stable footing.

3.  Prestimulate the bull

 

Manually prestimulating the bull for 10-15 seconds prior to inserting the probe can 
relax the animal, and shorten collection time.

4.  Try automatic mode first

 

Veterinarians have found that up to 90% of bulls can be quickly collected from using 
ElectroJac’s unique automatic mode.  Manual mode is most useful with older bulls 
that are more difficult to stimulate.

Questions? Call us at 800/621-8829 or 859/254-1221

 

2

Usage suggestions for ElectroJac 6

Summary of Contents for Electro Jac 6

Page 1: ...Operator s Manual...

Page 2: ......

Page 3: ...operation with optional dwell cable 7 Manual operation with wireless remote control 8 Manual operation with optional dwell cable 9 Troubleshooting 10 Frequently asked questions 11 Battery and AC batte...

Page 4: ...ri narians spread a bucket of sand over the enclosure s floor to increase a bull s footing and others have bulls stand in ankle deep sand to ensure stable footing 3 Prestimulate the bull Manually pres...

Page 5: ...handling the optional dwell box The on off switch and the dwell switch can be damaged if the box is not handled with care 5 After inserting the probe hold the bull s tail down to prevent the probe fr...

Page 6: ...Probe cable assembly 6901 Carrying case 6992 2 5 64 mm Bull probe 15 5 394 mm length 4 75 lbs 6993 3 76 mm Bull probe 15 5 394 mm length 6 25 lbs 6902 Replacement battery And your choice of probe siz...

Page 7: ...er the on off button or the dwell button Manual operation In manual mode the intensity is con trolled by adjusting the manual control Increasing voltage is applied to the probe s electrodes as the man...

Page 8: ...the red button on remote control for 2 seconds 5 After use wipe the probe and cables down with a sponge and a nontoxic nonabrasive cleaning solution Resetting the unit If the animal experiences extrem...

Page 9: ...4 The red dwell light will glow and the numeric display will indicate the progression through the unit s 40 cycles A glowing dot in the bottom right hand corner of the display indicates when power is...

Page 10: ...To prepare the unit a Set the Auto manual switch on the electronics instrument case to Manual b Set the Manual control on the electronics instrument case to Low c Plug one end of the probe cable to t...

Page 11: ...ac 6 must be prepared for use prior to beginning the operation To prepare the unit a Set the Auto manual switch on the electronics instrument case to Manual b Set the On off switch on the dwell contro...

Page 12: ...the unit is charging d If the charging circuit needs to be replaced call 800 621 8829 for technical support 4 What do I do if moisture gets in the unit If moisture gets in the unit allow the unit to d...

Page 13: ...ble 7 If needed would you send me drawings so I can repair the unit myself No due to legalities and to ensure proper operation and maintain the warranty only an authorized repair facility may repair E...

Page 14: ...he bottom from the electronics case by opening the latches on both sides of the case while carefully sup porting the relatively heavy case bottom 2 Remove red and black leads from the battery by pulli...

Page 15: ...returned freight prepaid Warranty ElectroJac 6 s fuse is located above the battery in the battery compart ment Fuse replacement 1 Remove the dwell cable if used and the probe cable 2 Unlatch the batte...

Page 16: ...Neogen Corporation 2012 Ideal and ElectroJac are registered trademarks of Neogen Corporation Lansing MI 48912 L2429 0112 800 621 8829 or 859 254 1221 www neogen com...