Neomatica. LLC. Tracker ADM50 GLONASS / GPS. Rev.1.2 dated 03.10.2018
6
3.2 Automatic switching-on by the charger connection
If this function is activated, the inclusion of the tracker is automatic, when it is connecting to
a charger or personal computer. Regardless of how the disabling occurred, using the Power
button or because the battery is completely discharged. By default, this feature is disabled.
The configuration performs locally - using the configurator via the USB interface or remotely
by sending commands via GPRS or SMS.
PENU X
X=0
– Automatic switching-on disabled.
X=1
– Automatic switching-on enabled.
3.3 Power button lock
If this function is activated, disabling of the tracker becomes impossible with the Power
button. Even so, switching-on the tracker and the function of determining the battery charge level
are still available. By default, the lock is disabled.
The configuration performs locally - using the configurator via the USB interface or
remotely by sending commands via GPRS or SMS.
POFF X
X=0
– Power button unlocked.
X=1
– Power button locked.
To disable the tracker using the button, you must disable the Power button lock.
Indication
4.1 Green LED - GLONASS/GPS module status
•
flashes three times during the period - GLONASS/GPS module is on, but there is no data
from it yet;
•
flashes twice during the period - there is data from the GLONASS/GPS module, but the data
is invalid;
•
flashes once during the period - there is data from the GLONASS/GPS module and the data
is valid;
•
no flashes - GLONASS / GPS module is turned off or the ADM50 is in a sleeping state.
In the beacon mode, the LED does not light regardless of the GLONASS/GPS module state
during sleep.