8.1.2
COUNTERS / TIME PROG / CLOCK menus
This menu contains the following sub-menus:
COUNTERS
TIME PROG
CLOCK
Caution
The name of the PCB is displayed. Check that it is actually the
PCB on which the setting must be made.
For more information, see
Browsing in the menus, page 18
Sub-menu COUNTERS
Tab.9
List of parameters AC: Appliance Counter
Parameter
Description
Unit
PCB
PCB
Number of hours of operation.
hours
available
available
Number of hours of burner operation since the last service.
hours
available
not available
Number of hours of operation since the last service.
hours
available
not available
Number of burner start-ups since the last service.
-
available
not available
Consumption in heating mode.
kWh
available
not available
Consumption in domestic hot water production mode.
kWh
available
not available
Number of hours of pump operation.
hours
available
not available
Number of pump start-ups.
-
available
not available
Tab.10 List of parameters CC: Circuit Counter
Parameter
Description
Unit
PCB
PCB
Number of hours of pump operation.
hours
not available available
Number of pump start-ups.
hours
not available available
Tab.11 List of parameters DC: Direct Hot Water Counter
Parameter
Description
Unit
PCB
PCB
Number of reversal valve cycles.
-
available
not available
Number of hours of reversal valve operation.
hours
available
not available
Number of burner start-ups in domestic hot water production mode. -
available
not available
Number of hours of burner operation in domestic hot water produc
tion mode.
hours
available
not available
Tab.12 List of parametersPC: Process Counter
Parameter
Description
Unit
PCB
PCB
Number of burner start-ups.
-
available
not available
Number of hours of burner operation.
hours
available
not available
8 Control panel settings IniControl 2
26
EF