Figure 13 Backup/Clear Data
Press the Save bu
�
on, and press “Yes” in the con
fir
ma
�o
n window that appears to compress
and backup all collected data to the USB
fl
ash disk. The document will automa
�
cally use the
backup date for its name.
Press the Reset bu
�
on, and press Yes in the con
fir
ma
�o
n window that appears to clear all
collected data. The device se
�
ngs will not be changed.
4.6 Status Bar
The bo
�
om
fi
eld on all display pages consists of the status bar, which displays the device's
opera
�
ng status, the current IP address, and the current date and
�
me. “OK” means that
the device is opera
�
ng normally. A 16-bit error code will be displayed in the form of a hex
number if there happens to be a malfunc
�o
n. The meaning of the error code is listed in
the following table.
Error code
Error
Bit-0
DC over voltage
Bit-1
DC under voltage
Bit-2
hardware error
Bit-3
Inverter over voltage
Bit-4
Frequency over
Bit-5
Frequency under
Bit-6
AC voltage RMS over
Bit-7
AC voltage RMS under
Bit-8
Peak AC voltage over
Bit-9
AC current RMS over
Bit-10
Peak AC current over
Bit-11
Temperature over
Bit-12
ADC error
Bit-13
GFDI fault indicator
Bit-14
Relay error (for some model)
Bit-15
PLC Communication Error
5. WEB INTERFACE
The BDG-256/BDG-256P3 informa
�
on can be accessed through two web pages. The
fir
st one is a
web server inside the BDG-256/BDG-256P3 gateway. The second one is a web server provided by
NEP, which access requires internet service.
MICROVIEWER m
o
nit
o
ring
w/ built-in
BDG-256/BDG-256P3
The local web portal built inside BDG-256/BDG-256P3 can be accessed through home network
without internet service. If there is internet service, however, remote monitoring can be accessed
through NEPVIEWER from anywhere at any
�
me
To access the web portal inside BDG-256/BDG-256P3, user only needs to type in the IP address of
BDG-256/BDG-256P3 on a web browser. (Please see Sec
�
on 4.4.1 for con
fi
guring the IP address of
BDG-256/BDG-256P3). The administra
�o
n page for inverter address can be accessed by
h
�
p://GATEWAY-IP/module (for example h
�
p://10.208.100.202/module)
Figure 14 MICROVIEWER monitoring
Figure 15 Inpu
�
ng inverter s/n through a webpage
10
09