13
8. SPECIFICATION
MODEL
BDM-300-240A(-D)
BDM-300-208A(-D)
INPUT(DC)
Max Recommended PV Power (Wp)
340
340
Max DC Open Circuit Voltage (Vdc)
60
60
Max DC Input Current (Adc)
12
12
MPPT Tracking Accuracy
>99.5%
>99.5%
MPPT Tracking Range (Vdc)
22-55
22-55
OUTPUT(AC)
Peak AC Output Power (Wac)
270
270
Rated AC Output Power (Wac)
250
250
Nominal Power Grid Voltage (Vac)
240
208
Allowable Power Grid Voltage (Vac)
211-264
(Adjustable
*
)
183-228
(Adjustable
*
)
Allowable Power Grid Frequency (Hz)
59.3-60.5
(Adjustable
*
)
59.3-60.5
(Adjustable
*
)
THD
<3%
(at rated power)
<3%
(at rated power)
Power Factor
>0.99
(at rated power)
>0.99
(at rated power)
SYSTEM
EFFICIENCY
CEC E
ffi
ciency
95.5%
95.5%
Night Time Tire Loss (W)
0.08
0.06
PROTECTION
FUNCTIONS
Over/Under Voltage Protec
�
on
Yes
Yes
Over/Under Frequency Protec
�
on
Yes
Yes
An
�
-Islanding Protec
�
on
Yes
Yes
Over Current Protec
�
on
Yes
Yes
Reverse DC Polarity Protec
�
on
Yes
Yes
Overload Protec
�
on
Yes
Yes
Ground Fault Detec
�
on
Integrated
Integrated
Protec
�
on Degree
NEMA-6
NEMA-6
Environment Temperature
-40
℃
~ +65
℃
-40
℃
~ +65
℃
Opera
�
ng Temperature
-40
℃
~ +85
℃
-40
℃
~ +85
℃
OTHER
PARAMETERS
Display
LED LIGHT
LED LIGHT
Communica
�
ons
POWERLINE
POWERLINE
Dimension (W-H-D mm)
180*186*25
180*186*25
Weight (Kg)
1.5
1.5
(* Per IEEE 1547A)
MODEL
BDM-300-AU(-D)
BDM-300-EU(-D)
INPUT(DC)
Max Recommended PV Power (Wp)
340
Vmax PV (absolute maximum) (Vdc)
60
PV Input Opera
�
ng Voltage Range (Vdc)
22-55
Maximum Opera
�
ng PV Input Current (Adc)
12
MPPT Tracking Accuracy
>99.5%
Isc PV (absolute maximum) (Adc)
28
Maximum Inverter Backfeed Current to the Array (Adc)
0
OUTPUT(AC)
Peak AC Output Power (W)
270
Rated AC Output Power (Wac)
250
Nominal Power Grid Voltage (Vac)
230
Current (maximum con
�
nuous) (Aac)
1.09
Current (inrush) (Peak and Dura
�
on)
12A, 15us
Nominal Frequency (Hz)
50
Power Factor
>0.99
(at rated power)
Maximum Output Fault Current (Aac)
2.2A peak
Maximum Output Overcurrent Protec
�
on (Aac)
6.3
SYSTEM
EFFICIENCY
CEC E
ffi
ciency
95.5%
Night Time Tare Loss (W)
0.07
PROTECTION
FUNCTIONS
Over/Under Voltage Protec
�
on
Yes
Over/Under Frequency Protec
�
on
Yes
An
�
-Islanding Protec
�
on
Yes
Over Current Protec
�
on
Yes
Reverse DC Polarity Protec
�
on
Yes
Overload Protec
�
on
Yes
Ground Fault Detec
�
on
Integrated
Protec
�
ve Class
I
IP Ra
�
ng
IP66 / IP67
Environment Temperature
-40
℃
~ +65
℃
Opera
�
ng Temperature
-40
℃
~ +85
℃
OTHER
PARAMETERS
Display
LED LIGHT
Communica
�
ons
POWERLINE
Dimension (W-H-D mm)
180*186*25
Weight (Kg)
1.5
15
14