SKG4-E Gas Fired Humidifier
Installation Instructions and User Manual
Page | - 54 -
Menu - Service
[Level 3 - Requires level 3 (or higher) password in order to access]
Sub-Menu
Setting
Default
Range
(
* indicates no configuration; display only)
Description/Notes
Status
Module 1 to 4
[6]
RunTime:
0.00hr
*
Displays the total runtime of the humidifier module.
ServOnTime:
0.00hr
*
Displays the operating time of the humidifier module, since the last servicing.
ServRunTime:
0.00hr
*
Displays the runtime of the humidifier module, since the last servicing.
OnTime:
0.00hr
*
Displays the total operating time of the humidifier module.
IgnitionCount:
0
*
Displays the number of times the module humidifier module has made a
complete ignition cycle.
ServiceDue:
Off
* (Off, On)
Displays whether the humidifier module is due for servicing.
Command
DrainSchedule:
-
00:00
Monday to Sunday
Event 1 to Event 6
Create a customized draining schedule with up to six events per day.
SysRequest:
None
None, Reset Alarms, Drain, Reset Counters,
Filling, WaterCalib, PurgeAir
Perform one of the following actions for the whole system: reset service counters,
initiate a drain cycle, reset warning alarms, fill the evaporation chamber, calibrate
the water level sensor or perform an air purge.
Mod1Request
None
None, Reset Alarms, Drain, Reset Counters,
Filling, WaterCalib, PurgeAir
Perform one of the following actions for the first humidifier module: reset service
counters, initiate a drain cycle, reset warning alarms, fill the evaporation chamber,
calibrate the water level sensor or perform an air purge.
Mod2Request
None
None, Reset Alarms, Drain, Reset Counters,
Filling, WaterCalib, PurgeAir
Perform one of the following actions for the second humidifier module: reset
service counters, initiate a drain cycle, reset warning alarms, fill the evaporation
chamber, calibrate the water level sensor or perform an air purge.
(Only appears when there is a second humidifier module.)
Mod3Request
None
None, Reset Alarms, Drain, Reset Counters,
Filling, WaterCalib, PurgeAir
Perform one of the following actions for the third humidifier module: reset service
counters, initiate a drain cycle, reset warning alarms, fill the evaporation chamber,
calibrate the water level sensor or perform an air purge.
(Only appears when there is a third humidifier module.)
Mod4Request
None
None, Reset Alarms, Drain, Reset Counters,
Filling, WaterCalib, PurgeAir
Perform one of the following actions for the fourth humidifier module: reset service
counters, initiate a drain cycle, reset warning alarms, fill the evaporation chamber,
calibrate the water level sensor or perform an air purge.
(Only appears when there is a fourth humidifier module.)