14
Betriebsanleitung Neptun Massagestation Edelstahl V.20181005
1,1 kW
2 kW
voltage
230-400 V/50 Hz
230 V/50 Hz
admission/ emission in kW
1,1/xx
2,0/1,6
flow rate l /min. max.
650
800
current consumption
see pump-nameplate
preliminary fuse
16 A träge
xx
line from the network
5 x 2,5 mm²
3 x 1,5 mm²
cable to the pump
4 x 2,5 mm²
3 x 1,5 mm²
motor protection from the factory 3,7 A
9,8 A
2,6 kW
3 kW
4 kW
voltage
230/400 V/50 Hz 230-400 V/50Hz 230-400 V/50Hz
admission/ emission in kW
2,6/2,1
3/2,6
4/3,3
flow rate l /min. max.
900
1.000
1.100
current consumption
see pump-nameplate
preliminary fuse
16 A, slow blow 16 A, slow blow 16 A, träge
line from the network
5 x 2,5 mm²
5 x 2,5 mm²
5 x 2,5 mm²
cable to the pump
4 x 2,5 mm²
4 x 2,5 mm²
4 x 2,5 mm²
motor protection from the factory 4,5 A
6,1 A
7 A
technical data of pumps
P1 und P2 (Kaltleiter) ist je nach Pumpentyp im Schaltkasten ausgeführt, jedoch
kein Anschluß notwendig.
P1 and P2 (PTC thermistor) are designed depending on the type of pump in the
control box, but no connection is necessary.
Massagestation Edelstahl_A4 14.12.18 08:57 Seite 14