E-Coder)R900
i
Installation and Maintenance Guide
3
2 Specifications
This section provides you with the specifications for the E-Coder)R900
i
.
Electrical Specifications
Transmitter Specifications
Environmental Conditions
Functional Specifications
Dimensions and Weight
Power
Lithium battery
Transmit Period
Every 14 seconds
Transmitter Channels
50
Channel Frequency
910-920 MHz
Output Power
Meets FCC Part 15.247
FCC Verification
Part 15.247
Operating Temperature
-22° to 149°F (-30° to 63°C)
Storage Temperature
-40° to 158°F (-40° to 70°C)
Operating Humidity
0 to 95% Condensing (Pit only)
Register Reading
8 digits (AMR)
9 digits (Visual)
MIU ID
10 digits
Dimensions
Refer to Figure 3 and Figure 2
Weight
Inside - 1.08 lbs. (490 grams)
Pit - 1.38 lbs. (625 grams)