E-Coder)R900
i
Installation and Maintenance Guide
29
Appendix A: E-Coder)R900
i
Flags
Description of Flags
Two tables in this appendix describe the volume represented by the 8th digit by meter size,
and the flags used the by E-Coder)R900
i
.
continued on next page
Table 6 8th Digit Resolution by Meter Size
Register Size
8th Digit Resolution - Least Significant Digit
Residential
(5/8" - 1" T-10)
1/10 Gallon
or
1/100 Cubic feet
Light Commercial and Industrial
(1-1/2" and 2" T-10; 1-1/2" - 4" HPT)
1 Gallon
or
1/10 Cubic feet
Large Commercial and Industrial
(6" - 12" HPT, HPPII and TRU/FLO)
10 Gallons
or
1 Cubic feet
Large Commercial and Industrial
(16" - 20" HPT)
100 Gallons
or
10 Cubic feet
Table 7 E-Coder)R900
i
Flags
Backflow Flag (Resets After 35 Days)
Based on reverse movement of the 8th digit. 8th digit is variable based on the meter size.
No backflow event
8th digit reversed less than 1 digit
Minor backflow event
8th digit reversed more than 1 digit up to 100 times the 8th digit
Major backflow event
8th digit reversed greater than 100 times the 8th digit
Summary of Contents for E-Coder)R900i
Page 2: ......
Page 3: ...E Coder R900i Installation and Maintenance Guide ...
Page 6: ......
Page 9: ...Contents E Coder R900i Installation and Maintenance Guide vii Glossary Index ...
Page 10: ...Notes Contents viii E Coder R900i Installation and Maintenance Guide ...
Page 12: ...x E Coder R900i Installation and Maintenance Guide Notes Figures ...
Page 14: ...xii E Coder R900i Installation and Maintenance Guide Notes Tables ...
Page 46: ...Glossary Notes 32 E Coder R900i Installation and Maintenance Guide ...
Page 50: ...36 E Coder R900i Installation and Maintenance Guide Notes Index ...
Page 51: ......