4. If Ethernet backhaul is used, check the status of the three lights on
the CPU board adjacent to the Ethernet connector.
These lights provide a visual indication of the link status, network
activity, and network speed.
l
The green Link Integrity light is lit when there is a valid
connection detected.
l
The yellow Activity light blinks on and off when activity is
detected on the wire.
l
The red light is on if a 100BASE-T link is detected and off
if a 10BASE-T link is detected.
Refer to Table 7.
Designator
Light Color
Description
D4
Green
Link Integrity
D5
Yellow
Activity
D6
Red
10/100
Table 7 – Lights on the CPU Board
5. After the R450 DC has been powered up for five minutes, remove
the USB flash drive from the CPU board.
Swiping the MIU
Before you can proceed with these steps, the R450 DC must be
set up in the N_SIGHT PLUS host software. See "Creating a
Collector" on page 87 and "Building a USB Drive for Collector
Configuration" on page 93 for instructions on setting up the R450
DC in the host software.
To verify that the R450 DC can receive readings from MIUs and can
synchronize with the N_SIGHT PLUS host software, complete the
steps on the following page.
30
R450 Data Collector Installation and Maintenance Guide
Chapter 3: Installation of the R450 DC