1. Assemble the 16-inch strut channels to the back of the box as
shown in Figure 10. Use the supplied 3/8-inch nuts and bolts
with the seal washers on the inside of the box to seal from
moisture. See Figure 11.
2. Torque the mounting bolt to 65 in-lb. (7.34 Nm).
3. Position the R450 DC so that the top of the box is 4 to 6 inches
below the top of the pole.
Figure 10 – Assembling Strut Channels
Figure 11 – Mounting Hardware Stack Detail
4. Attach the box to the pole using 2" strut clamps. Beginning
with the top strut channel.
5. Attach the top part of the unit to the top of the pole. See Figure
12.
6. Tighten the bolts with a wrench, as illustrated in Figure 13.
7. Attach the bottom part of the unit to the pole using 2" strut
clamps.
Figure 12 – Positioning the Strut Channel
R450 Data Collector Installation and Maintenance Guide
17
Chapter 3: Installation of the R450 DC
Summary of Contents for R450