Procedure
There are two different versions of the Novus Micro Secure. See Figure
47 and Figure 48 on page 43 for the differences. For the surveillance
version, you may have to connect the dry contact terminal block
outputs and the RS232 connector depending on your requirements.
Step 1: Wiring the Input and Output Connectors
1. Connect the load wiring to the output terminal block
(surveillance version) as labeled. Torque to 7.0 lb-in (0.8 Nm).
Figure 53 – Wire Input and Output Connectors
For the cable TV version, connect the load cable to the output
cable connector.
2. On the surveillance version, if used, connect the dry contact
terminal blocks and the RS232 or Ethernet connectors (also, see
the Appendix) according to Figure 68 on page 77.
If using a conduit, drill a 1/2-in. hole to attach a matching conduit.
3. Wire the input terminal block according to its label. Torque to
7.0 lb in. (0.8 Nm).
The Cable version has a 6-ft (2 m) permanently connected input
power cable with a NEMA 5-15P plug for 120V application. For
230V application, connect the line power to the input terminal block
through the provided 1/2-in. knockout hole.