High and Low Limit Fields
The data placed in the High Limit and Low Limit reading fields can be either left-justified or
right-justified. However, all unused leading or trailing characters in the field must be spaces.
Example
Using the same example from the Manual Meter Review section, if the low reading limit is
equal to the previous reading, the value in the Low Limit field can be any of the following:
l
Number of Dials = six...Low Limit = 001234 or 1234
l
Number of Dials = five...Low Limit = 00123 or 123
l
Number of Dials = four...Low Limit = 0012 or 12
The data in the High Limit field would need to be equivalent quantities:
l
Number of Dials = six...High Limit = 001350 or 1350
l
Number of Dials = five...High Limit = 00135 or 135
l
Number of Dials = four...High Limit = 0013 or 13
High Limit Field
Low Limit Field
Test Results
Contains nines.
Contains zeros.
All readings pass the high / low test.
Contains all spaces.
Contains all spaces.
Handheld does not attempt the test for
that account.
Contents equals Low
Limit field.
Contents equals High
Limit field.
All readings pass the high / low test.
Table 11 – Disabling the High / Low
If the Number of Dials field contains incorrect data, the handheld attempts, but does not
complete, the high / low test for that account. The meter reader receives a warning.
R900® Belt Clip Transceiver Users' Guide
29
Appendix
A:
N_SIGHT
®
Meter
Reading
and
Override
Summary of Contents for R900
Page 1: ...R900 Belt Clip Transceiver Users Guide ...
Page 2: ......
Page 3: ...R900 Belt Clip Transceiver Users Guide ...
Page 8: ...This page intentionally left blank ...
Page 12: ...This page intentionally left blank xii R900 Belt Clip Transceiver Users Guide Contents ...
Page 14: ...This page intentionally left blank xiv R900 Belt Clip Transceiver Users Guide Figures ...
Page 16: ...This page intentionally left blank xvi R900 Belt Clip Transceiver Users Guide Tables ...
Page 67: ......