HOW TO
…
Set Authorization-card operation (Zone 1/Relay)
Note: Authorization-card is also called header card, it authorizes users. By default, users can
operate properly, you can use an Authorization-card when you need to restrict user access
.
## The Authorization Cards must be Ordered separately and do not come with the ACKPWB6K
-
These Cards would be either EM or HID Format and could be any Site Code or User No.
-
These Cards once enrolled would not open the Lock when presented.
To Activate follow the steps below,
Press and Hold * for 2-
3 Sec’s until Red LED Flashes
<Enter>Admin Password #
015#<Read Card> <Read Card><Read Card> (Max 3 Cards for this Operation)
Note: If only one Authorization Card is required, simply read 1 Card and Exit programming
-
Exit Menu’s
To test this function, you would have existing PIN CODE or Card Users working on the Keypad.
If you present the Authorisation Card the Keypad will respond with 2 Short Beeps to Lock Users out
## When you present the Authorisation Card a second time the Keypad will respond with one long
beep, this will Unlock all users to access keypad again. Both PIN and Card Users.
NOTE: The only Code to work in this Mode is the Super Open User
To Set for Single Door mode, with Super-open password.
Press and Hold * for 2-
3 Sec’s until Red LED Flashes
<Enter>Admin Password #
03 1# - Single door mode (Default)
00 (8 digits #) Must be 8 digit Super-open password
-
Exit Menu’s
NEPTUNE