background image

USER'S MANUAL 

for KPX & Saturn LCD Keypads

Rev

 

1.1

 

D8x/D16x  Deluxe 

Hardware  &  Firmware  v8.x

Document  890-016

Refer  to  document  890-402  Navigator  Manual  for  operation  by  Ness  Navigator  Touch  Screen  keypad

www.msealarms.com.au

Summary of Contents for D16x Deluxe

Page 1: ...NUAL for KPX Saturn LCD Keypads Rev 1 1 D8x D16x Deluxe Hardware Firmware v8 x Document 890 016 Refer to document 890 402 Navigator Manual for operation by Ness Navigator Touch Screen keypad www msealarms com au ...

Page 2: ...necessary to either increase the physical separation between the Ness receiver and other devices or if possible change the radio frequency or channel of the other devices 2 Unauthorised tampering physical damage electrical interruptions such as mains failure electrical spikes or lightning 3 Solar power inverters are a known source of electrical interference Please ensure that this product and all ...

Page 3: ...ew Memory 16 Temporary Day Zones 17 AutoTime Features 18 AutoTime Operation 19 PROGRAMMING 20 Programming Options Table 21 User Code programming 22 Entry Exit Timer programming 23 Telephone Number programming 23 Real Time Clock programming 24 Monitoring Central station Audible 25 Remote operation by telephone 26 27 Ness Accessories 28 29 Troubleshooting 30 Installation Record 31 OPERATION SUMMARY ...

Page 4: ...NESS D8X D16X DELUXE CONTROL PANEL USER S MANUAL 4 WHAT S NEW IN D8X D16X DELUXE V8 ALL D8X D16X FEATURES DIALLER www msealarms com au ...

Page 5: ...y Delay Time and will not alarm unless you disarm the panel during this allowed time When an alarm occurs it can be reset with a User Code1 or by optional Radio Key or Access Card Fob2 otherwise it will reset at the end of Alarm Reset Time Resetting an alarm stops the sirens and strobe light If an alarm is not reset the sirens will stop after the programmed time default is 5 minutes and the strobe...

Page 6: ...Time action will begin in one minute DISPLAY TEST To display all the keypad icons press and hold the button for at least 2 seconds All the icons will be on while the button is held down Display Test can be activated at any time either in operating mode or any program mode The instructions in this manual relate to Ness KPX and Saturn keypads The KPX keypad is used in examples throughout this manual...

Page 7: ...d if using Areas Area 2 is disarmed Area 2 is armed if using Areas Home Mode is disarmed Panel is armed in Home Mode Day Mode enabled see page 20 ÓÛÓÑÎÇ Normal Memory mode selected New alarm s in memory Normal Receiving a radio signal If radio fitted A Radio Key or other radio device has low battery ÌßÓÐÛÎ Normal Internal Tamper Double Flash with long pause External Tamper Steady flash ÛÈÝÔËÜÛ Nor...

Page 8: ...Area can Arm and Disarm only that Area User Codes assigned to both Areas will operate both Areas simultaneously COMMON AREA ZONES Zones assigned to both Areas are Armed only when Area1 and Area2 are both Armed This by both Areas For example Office A and Office B operate as separate areas but the entrance foyer used by both offices is assigned to both areas meaning it will automatically Arm when bo...

Page 9: ...eypads can be beautiful as well as functional Saturn s elegant design adds a distinctive look and feel of luxury to your alarm system Available in White Black and Ocean Mist Saturn keypads are fully compatible with Ness D8x D16x control panels version 6 and later NESS ACCESS CONTROL D8x and D16x also have an access control option for arming disarming and controlling electric door locks The panels ...

Page 10: ...ING Sealed If any are Unsealed the siren will sound been automatically excluded You should disarm the panel check the premises and then arm again Continual warnings could mean there is may have to be manually excluded the auto exclude option is disabled the siren will sound for the duration of siren time default is 5 minutes TO ARM the panel by KEYPAD by RADIO KEY by ACCESS CARD or FOB Press If th...

Page 11: ...lly be programmed to be Arm Only codes An Arm Only code can Arm the system but it cannot Disarm See page 22 for User Codes programming However if an Arm Only code is assigned to a radio key the radio key OFF button will arm and disarm AUTO RE ARM Your panel may optionally be programmed for Auto Re Arm to help prevent accidental disarming Auto Re Arm checks that you have entered the sealed for a pe...

Page 12: ...d if the panel is fully disarmed or if only Area2 is armed Home Mode is not available when Area 1 is armed The panel can be armed in Home mode if Area2 is already armed on these conditions Mode armed not the reverse Area 2 and Home Mode are armed Note Home Mode arming when Area2 is armed cannot be done by Radio Key or by keyswitch to arm HOME Mode by KEYPAD by RADIO KEY Press If the HOME MONITOR S...

Page 13: ... YOUR INSTALLER DURESS ALARMS CAN ONLY USED BY SYSTEMS WHICH ARE MONITORED BY A CENTRAL STATION THE DURESS ALARM CAN BE PROGRAMMED TO SOUND THE INTERNAL SIREN RESET OUTPUT THIS OPTION IS OFF BY DEFAULT PANIC alarm by KEYPAD by RADIO KEY Press star keys together NOTE Your panel may be programmed for DOUBLE PRESS RADIO PANIC To operate press and hold the Panic button until the transmit LED turns on ...

Page 14: ...nstaller And sends a Fire Alarm report by dialler If this option has been enabled by your installer and the system is monitored by a central station Keypad MEDICAL alarm by KEYPAD Press Sends a Medical Alarm report by dialler If this option has been enabled by your installer and the system is monitored by a central station The Medical Alarm does not sound the sirens www msealarms com au ...

Page 15: ...cally included next time the panel is Disarmed Zones can be manually included by the same method as Excluding Simply use the ZONE NO se lights to be Included NOTES EXCLUDE E works only when the panel is Disarmed EXCLUDE User Code E works in any state EXCLUDE User Code E How to EXCLUDE by KEYPAD Press If the EXCLUDE SHORTCUT is enabled or press USER CODE The Exclude light will turn on then press ZO...

Page 16: ...EMORY by KEYPAD Press If the VIEW MEMORY SHORTCUT is enabled or press USER CODE The Memory light will turn on Press The most recent event will be displayed Press The next most recent event will be displayed Press and so on up to 30 events Press to exit Memory Mode KEYPAD DISPLAY INDICATORS IN MEMORY MODE KEYPAD ICON MEMORY EVENT Zone numbers 1 8 or 1 16 Zone alarm no icons displayed Panel Disarmed...

Page 17: ...ch on the door For example in a shop you could enable Day Mode to alert you when a customer enters the front door You can also enable additional Temporary Day Zones to monitor switches on for example the rear door or the fridge doors COMMANDS Accessed from normal operating mode Enter Selection Mode Press P followed by E when in operating mode to enter Temporary Day Zone selection mode Zone Selecti...

Page 18: ...PUTS ON or OFF at pre programmed times every day once a week anytime Automate doors sprinkler systems lights and more ENABLE DISABLE USER CODES depending on the time of day or day of the week Allows managers to grant users access to the system at selected times and deny after hours entry This applies to keypad codes only not radio keys or prox fobs If you find that the panel sometimes does not res...

Page 19: ...s You are working back late and at 5 55pm your keypad begins to beep Since you re not ready to arm the system yet enter your user code without pressing E at the keypad The warning beeps will stop and arming will be delayed by one hour At 6 55pm the warning beeps will start again followed by automatic arming if you don t delay the event again Any AutoTime event can be postponed not just arming You ...

Page 20: ...y Time if you need more or less time to exit and enter the premises REAL TIME CLOCK Some features such as AutoTime rely on the onboard Real Time Clock Set the current date and time to ensure events take place as expected You will need to adjust the Hours setting when Daylight Savings starts and ends TELEPHONE NUMBER If your panel is programmed for Audible Monitoring the panel s dialler will make a...

Page 21: ...26 P226E 27 P227E 28 P228E USER CODE OPTION NO KEYPAD PIN 29 P229E 30 P230E 31 P231E 32 P232E 33 P233E 34 P234E 35 P235E 36 P236E 37 P237E 38 P238E 39 P239E 40 P240E 41 P241E 42 P242E 43 P243E 44 P244E 45 P245E 46 P246E 47 P247E 48 P248E 49 P249E 50 P250E 51 P251E 52 P252E 53 P253E 54 P254E 55 P255E 56 P256E OPTION NO DESCRIPTION DEFAULT COMMENT P26E Entry Delay Time 1 20 20 sec P27E Entry Delay T...

Page 22: ...d code does not need to be deleted first The new code will overwrite the old code Programming USER CODES STEP KEYSTROKES DESCRIPTION COMMENT 1 MASTER CODE Enters User Program Mode The Program light will turn on 2 OPTION NO Enter the 3 digit option number for the user code being pro grammed The existing user code if any will be displayed by the keypad one digit at a time 3 NEW CODE NEW CODE Enter t...

Page 23: ...rogram light will turn off Factory default timer settings are listed on page 21 Programming the FOLLOW ME TELEPHONE NUMBER STEP KEYSTROKES DESCRIPTION COMMENT 1 MASTER CODE Enters User Program Mode The Program light will turn on 2 Enter the option number for Fol low Me Telephone Number The existing telephone number if any will be dis played by the keypad one digit at a time 3 NEW TELEPHONE NUMBER ...

Page 24: ...en 01 and 12 P344E YEAR Enter a value between 00 and 63 2000 2063 P345E DAY OF THE WEEK Enter a value between 1 and 7 1 Sunday Enter the option number for one of the real Time Clock options The existing value if any will be displayed by the keypad one digit at a time 3 NEW VALUE Enter the new time in seconds Example enter 25 seconds as 25 E The new time will be dis played by the keypad one digit a...

Page 25: ...ssages clearly stating the alarm condition being reported The user can then acknowledge the alarm and hang up or enter a remote control menu which ALARM MESSAGE TRANSMISSION Alarm reports are sent to the Primary P70E and Secondary P71E telephone numbers or only to the Follow Me phone number P00E if programmed ALARM MESSAGE FORMAT The alarm message starts with the introduction This is a security sy...

Page 26: ...To exclude or include hang up press STAR then PRESS HASH The user presses 1 to arm or disarm the system and the voice prompt continues To arm Press 1 To disarm Press 2 To return Press STAR The user presses 1 to arm and the voice prompt continues with either of these messages TO CONNECT TO THE PANEL BY TELEPHONE METHOD 1 The connection is initiated by the panel during an alarm message METHOD 2 The ...

Page 27: ...ress HASH The user presses 2 to control outputs and the voice prompt continues with the message Double press the selected auxiliary output 1 to 8 Then press STAR to activate or HASH to turn off the selected output Press STAR to return The user presses 33 STAR and the voice prompt continues Auxiliary 3 ON The user presses 33 HASH and the voice prompt continues Auxiliary 3 OFF The user presses 32 HA...

Page 28: ...animal NESS CCTV PRODUCTS The wide range of Ness CCTV equipment allows your installer to design a professional state of the art system for your home office shop or factory Ness cameras include analogue or IP based dome cameras Infra red illuminated cameras miniature hidden cameras and professional digital cameras Ness DVRs are available in 4 8 or 16 channel models in standard definition or full 10...

Page 29: ...he sounder and radio transmitter A single battery powers the smoke detector and the transmitter Includes 9V lithium battery NESS RADIO KEYPAD A unique fully portable radio keypad The Ness Radio Keypad provides totally wireless Arming Disarming of the control panel Also operates Home Mode and provides a Panic alarm The Ness Radio Keypad is suitable for use as a portable keypad or for adding an extr...

Page 30: ... mode Press E to exit Exclude mode TAMPER light flashing The 24 hour Tamper input has alarmed Siren tamper or box tamper Call your installer ALARM MEMORY light is flashing There are alarms in memory To clear the ALARM MEMORY light view the Alarm memory otherwise the light will clear next time you arm the panel Cannot enter Program Mode The panel is armed Or you may be attempting to enter program m...

Page 31: ... ß Ûò ò Î Ý ô ß Ñ ô ò Û Ñ ß Ûò ò Î Ý ô ß Ñ ô ò ï îð íç ÐîðïÛ ÐîîðÛ ÐîíçÛ Ó Ý î îï ìð ÐîðîÛ ÐîîïÛ ÐîìðÛ í îî ìï ÐîðíÛ ÐîîîÛ ÐîìïÛ ì îí ìî ÐîðìÛ ÐîîíÛ ÐîìîÛ ë îì ìí ÐîðëÛ ÐîîìÛ ÐîìíÛ ê îë ìì ÐîðêÛ ÐîîëÛ ÐîììÛ é îê ìë ÐîðéÛ ÐîîêÛ ÐîìëÛ è îé ìê ÐîðèÛ ÐîîéÛ ÐîìêÛ ç îè ìé ÐîðçÛ ÐîîèÛ ÐîìéÛ ïð îç ìè ÐîïðÛ ÐîîçÛ ÐîìèÛ ïï íð ìç ÐîïïÛ ÐîíðÛ ÐîìçÛ ïî íï ëð ÐîïîÛ ÐîíïÛ ÐîëðÛ ïí íî ëï ÐîïíÛ ÐîíîÛ ÐîëïÛ ïì íí ë...

Page 32: ...Duress allows the user to send a silent duress report while disarming if the system is being monitored by a central station Press 5 6 8 OR 9 USER CODE Add one these digits in front of a user code when disarming This sequence will disarm the panel and send a Duress report by dialler to the central station REPORT KEYPAD DURESS must be enabled EXCLUDE ZONES EXCLUDE E can only be used when the panel i...