Programming
17
Installation and Programming manual
5-3
Programming from a PC
Only BUS-connectable Ivy units can be programmed via PC. The
SmartLeague software will allow you to program/change the
previously mentioned parameters/settings of the Ivy unit.
PATTERN
Additionally, the software application allows you to program the
“patterns”, that is to say, the type of signalling, duration and volume
of the audible signals.
Using the SmartLeague software programme, open a “SmartLiving”
solution, select the Sounderflasher option from the control panel
layout (on the right side of the page) then, access the
“Programming” section (on the left side of the page) which contains
the parameters of each pattern:
•
Pattern description
- 16 character description of the pattern
•
Activate sounder
- enables/disables sounderflasher activation
•
Duration (sounder)
- sounder activation time, expressed in
seconds (from 1 to 125) or in minutes (from 1 to 125)
•
Sound type
- the sound of the audible signal; 5 tones available
•
Volume
- 17 volume levels available
•
Activate flasher
- enable/disable flasher activation
•
Duration (flasher)
- flasher activation time, expressed in
seconds, minutes or “ Endless”. If “ Endless” is selected, the
flasher will signal continuously or at least until receives a cut-off
pattern signal. If the event that triggers the “ Endless” signalling
mode is a zone alarm, terminal tamper, partition alarm, partition
tamper the flasher will be cut-off by memory reset operations.
•
Flash mode
- 4 visual signals are available.
-
1=36 flash/min
-
2=46 flash/min
-
3=56 flash/min
-
4=On solid
•
Activate STATUS LED
- enable/disable activation of the
STATUS LED
•
Activate PRG LED
- enable/disable activation of the PRG LED
•
Activate TAMPER output
- enable/disable activation of the
TAMPER output
•
Activate FAULT output
- enable/disable activation of the
FAULT output