C07100DC023
65
Cleaning the metering stem
slit. This must be done only
with a soft, non-metallic
instrument. The slit must
not be enlarged and the
washer not damaged.
Unscrewing
of
the
float
assembly. These screws are put
under lacquer seals before the
device leaves the factory in
order to prevent unauthorized
persons dismantling the oil
control.
Should these seals be broken,
unauthorized tampering with
the oil control has taken place.
Lifting out the complete float assembly: When the attachment screws
have been removed, the complete float asssembly can be lifted out
upwards. If the float assembly must be replaced by a new one
because of a defect, the flows must be checked and, if necessary,
corrected (see Diagrams 8 and 9).