11 of 24
3.3.4. Minimum air se�ng.
The adjustment knob for the minimum air intake can be found
underneath the stove, on the air flap assembly. It is factory set. This
knob allows you to increase, decrease or completely close the
permanent air intake.
Adjust this knob according to your chimney’s draught, when the
chimney is at its opera�ng temperature and using an accurate flue
draught gauge. See sec�on 2.1.1, Chimney height requirements, for
the recommended flue dra�.
Minimum air screw open
(this is the factory se�ng, suitable for a
normal flue draught).
Minimum air screw closed or nearly closed
(in the case of an excessively strong flue
draught)
3.3.5. Remote Control (op�onal)
This stove has the op�on of remote control.
Fi�ng the remote control motor:
At the rear of the appliance you will see the motor fi�ng bracket.
This incorporates a magnet and the mechanism fric�on plate. The fric�on plate is
hinged. To fit the motor, this fric�on plate needs to be detached from the magnet
and swing to the le�. The motor can now be slipped into place. The magnet
retains the motor.
Fig. 15
Fig. 16
Adjustment knob
Fig. 13
Fig. 14
Summary of Contents for M43
Page 2: ...2 of 24 ...
Page 19: ...19 of 24 7 8 9 10 ...
Page 20: ...20 of 24 7 DIMENSIONS ...
Page 22: ...22 of 24 ...
Page 23: ...23 of 24 ...
Page 24: ...24 of 24 SOTO DE LA MARINA CANTABRIA Apdo de correos 208 SANTANDER C07100DC676_1 ED 04 2020 ...