220-0000022 rev03

ENE3400-P and ENE3400-S

E3 Network Extenders: Single Line Provider and Subscriber

Installation

1. Unpack and inspect the equipment.

The following components should be included:

          1 ENE3400
          1 power supply

If there is any visible damage, do not attempt to connect the device. Contact Customer Support at 1-
877-638-2638 (001-603-427-0600 for international customers) or Support@NetToNet.com.

2. Power up the ENE3400.

Plug the power supply into the back of the ENE3400 and connect it to the power source. Verify that 
the Power LED is illuminated.

3. Verify switch configuration.

Ensure that the switches on the back of the ENE3400 are positioned correctly to achieve the desired 
settings for your connection. Switches are numbered from left to right; Switch #1 is on the left and 
Switch #2 is on the right.

Installation Instructions

 

CAUTION

Net to Net Technologies strongly recommends the use of proper electrostatic discharge (ESD) precautions when 
handling this equipment. 

Tx

Rx

Power Adapter

Config

Fast Ethernet Connection

5V DC

E3 Connection

  

E3 Network Extender 3400

ENE3400-S

Lnk

Alm

Power

100

Act

Lnk

E3 Connection

Fast Ethernet Connection

  

NOTE

The Fast Ethernet 100, Act and Lnk LEDs will remain illuminated until the E3 link has been established.

Summary of Contents for ENE3400-P

Page 1: ... Power LED is illuminated 3 Verify switch configuration Ensure that the switches on the back of the ENE3400 are positioned correctly to achieve the desired settings for your connection Switches are numbered from left to right Switch 1 is on the left and Switch 2 is on the right Installation Instructions CAUTION Net to Net Technologies strongly recommends the use of proper electrostatic discharge E...

Page 2: ...ction has been established If the Fast Ethernet 100 LED is also illuminated then a 100 Mbps connection has been established Tx Rx Power Adapter Config Fast Ethernet Connection 5V DC E3 Connection Switch 1 is not used on the subscriber unit ENE3400 S Clock source configuration for the ENE3400 S is determined by the switch setting on the provider unit ENE3400 P Switch 1 ENE34000 P only Clock Source ...

Page 3: ... the unit s partner ENE3400 will have LOS as well Note When an ENE3400 has LOS the Ethernet link will be disabled and the Ethernet 100 Act and Lnk LEDs will show solid illumination E3 Connection Alm no illumination E3 is operational Note If the E3 Lnk LED also remains unlit then the unit has LOS solid amber Remote Alarm Indication RAI The outgoing connection from the unit has been lost no data is ...

Page 4: ...eavy traffic Note A solid amber Fast Ethernet Act LED can also denote an E3 Alarm if the Fast Ethernet 100 and Lnk LEDs show solid illumination and the E3 Lnk LED remains unlit no illumination no Ethernet activity Either there is no Ethernet link or a link exists but there is no activity Fast Ethernet Lnk solid green Ethernet connection is established If the Fast Ethernet Lnk LED is illuminated bu...