3.0   ADDITIONAL INFORMATION 

 

3.1   LED Indications 

 

 
(A pulsing LED blinks steadily at a rate of once per second. A flashing LED blinks at a 

more rapid, less constant rate.) 

 

3.2   Regulatory Compliance 

 

 
 

T1 RJ45 PINOUT

Pin 1 Rx Ring

Pin 5 Tx Tip

Pin 2 Rx Tip

Pin 6 not used

Pin 3 not used Pin 7 not used

Pin 4 Tx Ring

Pin 8 not used

     

 
LED

State

Indication

Additional Information

Port 1 
Lnk and 
Port 2 
Lnk

 

flashing 
green

T1 connection is established and 
active 

Traffic is flowing. 

solid green

problematic T1 connection 

A connection exists but there is indication of 
a problem with the T1 line. 

no 
illumination

Red Alarm

 

The incoming connection to the 
UIM-2T1 has been lost; no data is 
being received. 

If the outgoing connection from the UIM-
2T1 has also been lost then the remote T1 
equipment is in Red Alarm as well. 

Port 1 
Alm and 
Port 2 
Alm

 

no 
illumination

T1 is operational 

An established T1 link has no alarm 
indications and is operational UNLESS the 
T1 Lnk LED remains unlit as well, in which 
case the UIM-2T1 is in Red Alarm. 

solid amber

Yellow Alarm

 

The outgoing connection from the 
UIM-2T1 has been lost; no data is 
being transmitted. 

The remote T1 equipment has lost its 
incoming connection and is in Red Alarm. 

pulsing 
amber

Blue Alarm

 

An indirect connection has been 
lost; the UIM-2T1 may no longer 
be receiving data from the remote 
T1 equipment. 

The remote T1 equipment has lost a 
connection with an intermediate device and 
is in Red or Yellow Alarm. 

N

OTE

The following regulatory compliance information applies to the UIM-2T1 as installed in a Mini DSLAM or on a 
MUM in an IP DSLAM. 

220-0000084 rev 01

Summary of Contents for UIM-2T1

Page 1: ... facing the Configuration Switches Port 1 switches are on the left and Port 2 switches are on the right Switches for both ports are numbered from left to right 1 8 Installation Instructions CAUTION Net to Net Technologies strongly recommends the use of proper electrostatic discharge ESD precautions when handling this equipment NOTE Port 2 Configuration Switches on the UIM 2T1 are NOT USED frame ty...

Page 2: ...blic network B8ZS line encoding helps prevent loss of synchronization between the UIM 2T1 and remote T1 equipment by using bipolar violations to guarantee the presence of pulses in the T1 line 1 2 2 2 Alternate Mark Inversion Alternate Mark Inversion AMI simply alternates positive and negative pulses Although AMI links typically encounter long strings of zeros which can potentially cause loss of s...

Page 3: ...MUM faceplate at the selected port opening such that the UIM 2T1 circuit board is facedown and the UIM 2T1 label shows through the MUM port opening with the UIM 2T1 model name along the right hand edge z Ensure that the mounting holes on the UIM 2T1 are lined up with the corresponding pems on the MUM circuit board and that the board to board connector key pins are properly aligned z Gently press d...

Page 4: ...he screws aside z Select a port on the Mini DSLAM for UIM 2T1 installation either port 1 or 2 may be used Although not required for operational purposes if redundancy is desired two UIMs may be installed on a Mini DSLAM one in each port z Remove the blanking plate from the selected port z Carefully slide the faceplate of the UIM 2T1 under the inside lip of the Mini DSLAM at the selected port openi...

Page 5: ...1 provider equipment See Net to Net s T1 Loop Bonding Product to Product Feature Compatability list http www nettonet com support docs 230 0000034 Plug the T1 cables into the T1 RJ45 Ports on the UIM 2T1 faceplate the order of connection is not important Verify both connections the Port 1 and Port 2 Lnk LEDs on the UIM 2T1 faceplate will flash green to indicate the connections are established and ...

Page 6: ...ing connection from the UIM 2T1 has also been lost then the remote T1 equipment is in Red Alarm as well Port 1 Alm and Port 2 Alm no illumination T1 is operational An established T1 link has no alarm indications and is operational UNLESS the T1 Lnk LED remains unlit as well in which case the UIM 2T1 is in Red Alarm solid amber Yellow Alarm The outgoing connection from the UIM 2T1 has been lost no ...

Page 7: ... RJ 48C TNE1500 X TNE1520 X UIM T1 or UIM 2T1 In the unlikely event that this equipment harms the telephone network the telephone company can temporarily disconnect your service The telephone company will try to warn you in advance of any such disconnection but if advance notice isn t practical it may disconnect the service first and notify you as soon as possible thereafter In the event such a di...

Page 8: ...nctions may give the telecommunications company cause to request the user to disconnect the equipment Users should ensure for their own protection that the electrical ground connections of the power utility telephone lines and internal metallic water pipe system if present are connected together This precaution may be particularly important in rural areas Caution Users should not attempt to make s...

Reviews: