background image

LIB-3 0 4  & LIB-3 0 6  In st a lla t io n  Gu id e  

 

 

 

DOC IG-3 0 X-V1 .2  

 

25 of 37 

Yo u  c a n  c h a n g e  t h e  d e fa u lt s  v ia  t h e  CLI. 

No te :

 y o u  m a y  w a n t  t o  s a v e  t h e  

e xis t in g  c o n fig  t o  s t a r t u p  c o n fig  fir s t  b y  u s in g  t h e  

c o p y  ru n n in g -c o n fig

 

c o m m a n d . Se e  t h e  CLI Re fe r e n c e  m a n u a l fo r  d e t a ils . T o  m a n u a lly  

c o n fig u r e  t h e  IP a d d r e s s : 

 

1 .

 

At  t h e  c o m m a n d  p r o m p t  t y p e   #

 c o n fig u re  te rm in al

 a n d  p r e s s  t h e  

En t e r  k e y  t o  e n t e r  c o n fig  m o d e .  

2 .

 

En t e r  t h e  c o m m a n d  ( c o n fig ) #  

in te rfac e  v lan  1

 a n d  p r e s s  t h e  En t e r  

k e y  t o  e n t e r  t h e  in t e r fa c e  c o n fig  m o d e .  

3 .

 

Se t  t h e  IP t o  1 9 2 .1 6 8 .1 .1 1 0  a n d  s u b n e t  t o  2 5 5 .2 5 5 .2 5 5 .0  ( s u b s t it u t e  

w h a t  y o u  w o u ld  lik e  t h e  s t a t ic  IP a n d  s u b n e t  t o  b e ) . Yo u  c a n  c h a n g e  

t h e  c u r r e n t  IP a d d r e s s  u s in g  t h e  fo llo w in g  c o m m a n d : 

( c o n fig -if-v lan ) #  ip   ad d re s s   1 9 2 .1 6 8 .1 .1 1 0   2 5 5 .2 5 5 .2 5 5 .0  

Se e  t h e  LIB-3 0 6  CLI Re fe r e n c e  m a n u a l fo r  CLI c o m m a n d  in fo r m a t io n   fo r  

CLI d e t a ils . 

 

4 .

 

T o  v e r ify  t h e  c h a n g e , y o u  c a n  lo g  in  t o  t h e  LIB-3 0 6  We b  GUI u s in g  IP 

a d d r e s s  1 9 2 .1 6 8 .1 .1 1 0 . Se e  t h e  LIB-3 0 6  We b  Us e r  Gu id e  fo r  m o r e  

in fo r m a t io n . 

 

2.13 Login using PuTTY Terminal Emulator Software 

1 .

 

St a r t  a  Pu T T Y s e s s io n . In  t h e  Pu TT Y d ia lo g  b o x in  t h e  “Ho s t  Na m e  {o r  

IP Ad d r e ss}” fie ld , e n t e r  t h e  IP a d d r e ss o f t h e  swit ch  ( e .g., 

1 9 2 .1 6 8 .1 .1 1 0 ) . In  t h e  Po r t  fie ld , e n t e r  2 2 .  

2 .

 

Na m e  t h e  se ssio n  in  t h e  “Sa ve d  Se ssio n s” fie ld  ( e .g., a s LIB-3 0 6  SW) . 

3 .

 

Clic k  t h e  

Sav e

 b u t t o n  a n d  t h e  d ia lo g  b o x d is p la y s . 

4 .

 

Clic k  t h e  

Op e n

 b u t t o n  t o  la u n c h  t h e  lo g in  s c r e e n .  

No te :

 If a  Se c u r it y  Ale r t  d is p la y s , c lic k  YES, if y o u  t r u s t  t h e  h o s t  a n d  

t h e  k e y  w ill b e  a d d e d  t o  t h e  Pu T T Y c a c h e . Clic k  NO if y o u  d o  

n o t  w a n t  t o  r e g is t e r  t h e  k e y  fo r  t h is  s e s s io n .  

5 .

 

At  t h e  lo g in  p r o m p t , t y p e   “

ad m in

” ( d e fa u lt / lo we r ca se ) . 

6 .

 

Pr e s s  t h e  En t e r  k e y  t w ic e  t o  b r in g  u p  t h e  Ro o t  ( t o p )  le v e l c o m m a n d s  

a s  s h o w n  b e lo w . 

 

Summary of Contents for LIB-304

Page 1: ...MANUAL LIB 304 LIB 306 Installation Guide Installation Guide ...

Page 2: ... an officer of Net2 Ed ge d oes so at th eir own r isk an d agr ees to fu lly in d em n ify Net 2 Ed ge for an y d am ages th at m ay r esu lt fr om su ch u se or sale Attention th is p r od u ct like all electr on ic p r od u cts u ses sem icon d u ctor s th at can b e d am aged b y ESD electr ostatic d isch ar ge Always ob ser ve ap p r op r iate p r ecau tion s wh en h an d lin g War n in g Pot...

Page 3: ...ted to v 2 1 3 wh ich ad d s DDMI HQoS JSON LLDP MED MEP BFD MPLS TP PFC Tr affic Test Loop UDLD an d Y 1 5 6 4 su p p or t C 2 5 th Sep t 1 6 Up d ate th e Rack Mou n t In stallation in form ation D 2 6 th Jan 1 7 Re Br an d ed to Net2 Ed ge 1 0 0 7 th Nov 1 7 Fir st Release to in clu d e LIB 3 0 4 1 1 1 0 th Nov 1 7 Up d ated Tab le of Con ten ts 1 2 2 6 th Feb 1 8 Up d ated PSU op er atin g fr ...

Page 4: ...e s All oth er tr ad em ar ks or r egister ed tr ad em a r ks m en tion ed h er ein ar e th e p r op er ty of th eir r esp ective h old er s Copyright restrictions 2 0 1 8 Net2 Ed ge Ltd All r igh ts r eser ved No p ar t of th is wor k m ay b e r ep r od u ced or u sed in an y for m or b y an y m ean s g r ap h ic electr on ic or m ech an ical with ou t wr itten p er m ission fr om Net2 Ed ge Plea...

Page 5: ...8 1 4 Featu r es 1 0 1 5 Sp ecification s 1 1 1 6 Related Man u als an d Help 1 2 2 Installation 1 3 2 1 Un p ackin g Package Con ten ts 1 3 2 2 In stall Cau tion s an d War n in gs 1 3 2 3 In stallation Location 1 4 2 3 1 Rack Mount Installation 1 4 2 4 Gr ou n d in g an d Wir in g Recom m en d ation s 1 4 2 5 Rear Pan el 1 5 2 6 Fr on t Pan el 1 6 2 7 Con n ectin g Power 2 0 2 8 In stallin g SFP...

Page 6: ...r Softwar e 2 5 2 1 4 Login Usin g Teln et 2 6 2 6 2 1 5 Login Usin g th e Web In ter face 2 6 2 1 6 Re Access th e Web GUI via CLI Com m an d s 2 7 2 1 7 Switch in g MGMT PORT 1 Mod es 2 7 2 1 8 Con figu r e th e Defau lt Man agem en t Por t as a Data Por t 2 8 2 1 9 Pr od u ct Registr ation 2 9 3 Troubleshooting 3 0 3 1 Recor d in g Mod el an d System In for m ation 3 0 4 Service Warranty and Te...

Page 7: ...r for m an ce Mon itor in g an d IEEE 8 0 2 3 ah Lin k OAM ar e stan d ar d featu r es Th e p r od u cts su p p or t ad van ced featu r es su ch as IPv 4 an d IPv6 VLANs QoS b an d wid th allocation r in g p r otection ju m b o fr am es an d n u m er ou s secu r ity featu r es Th e p r od u cts can b e m an aged an d p r ovision ed with Net2 Ed ge Kan r i EMS via a Web in ter face CLI or SNMP v1 v...

Page 8: ...b p s SFP p or ts In clu d es IEEE 1 5 8 8 v2 with RFC 2 5 4 4 Tr affic Gen er ation LIB 3 0 6 4 2 4 xTP 2 xSFP NID Fou r 1 0 1 0 0 1 0 0 0 Mb p s RJ4 5 p or ts Two 1 0 0 1 0 0 0 Mb p s SFP p or ts In clu d es IEEE 1 5 8 8 v2 with RFC 2 5 4 4 Tr affic Gen er ation 1 3 Applications Th e LIB 3 0 4 LIB 3 0 6 ar e d esign ed to su p p or t a wid e r an ge of MEF b ased Car r ier Eth er n et ser vices ...

Page 9: ...LIB 3 0 4 LIB 3 0 6 In stallation Gu id e DOC IG 3 0 X V1 2 9 of 37 CE Services Exam ple Cloud Services Exam ple E LAN Services Exam ple E Line Services Example ...

Page 10: ...EEE 1 5 8 8 v2 PTP Pr ecision Tim e Pr otocol AC p ower in p u t 1 0 0 V 2 4 0 VAC Ju m b o Fr am e Su p p or t 1 0 2 4 0 b ytes m axim u m Wir e sp eed loop b acks RFC 2 5 4 4 Tr affic Gen er ation an d Rep or ts Last Gasp Dyin g Gasp n otification via SNMP tr ap Mon itor Rx an d Tx Dyin g Gasp for each p or t SNMP tr ap s con figu r ab le System War m Star t Cold Star t In ter face Lin k Up Lin ...

Page 11: ...ab el Switch in g PFC 8 0 2 1 Qb b Pr ior ity Flow Con tr ol Tr affic Test Loop Y 1 5 6 4 RFC2 5 4 4 an d TT Loop fu n ction s UDLD Un i Dir ection al Lin k Detection p r otocol su p p or t RFC 5 1 7 1 Y 1 5 6 4 Tests an d Rep or ts 1 5 Specifications Standards IEEE 8 0 2 3 for 1 0 Base T IEEE 8 0 2 3 u for 1 0 0 Base TX IEEE 8 0 2 3 z for 1 0 0 0 Base X IEEE 8 0 2 3 ab for 1 0 0 0 Base T IEEE 8 0...

Page 12: ...d active u sin g stan d ar d 1 G MM SFP m od u les Maxim u m p ower con su m p tion 1 0 watts Environm ent Op er atin g Tem p er a tu r e 2 0 C to 5 0 C Stor age Tem p er atu r e 4 0 C to 7 0 C Hu m id ity 5 to 9 0 n on con d en sin g Warranty 1 Yea r Har d war e war r an ty 9 0 d ays Softwar e war r an ty Support Su p p or t p ackages availab le for Tech n ical Su p p or t Har d war e Su p p or t...

Page 13: ... e LIB 3 0 4 LIB 3 0 6 Failu r e to ob ser ve th is cau tion cou ld r esu lt in p oor p er for m an ce or d a m age to th e eq u ip m en t CAUTION In stall th e u n it in an op er atin g en vir on m en t wh er e th e tem p er atu r e r a n ge is b etween 2 0 C to 5 0 C with r elative h u m id ity of 5 to 9 0 n on con d en sin g Failu r e to ob ser ve th is cau tion cou ld r esu lt in p oor eq u ip...

Page 14: ...th e u n it for ven tilation p u r p oses 2 3 1 Rack Mount Installation Th e LIB 3 0 4 or LIB 3 0 6 can b e r ack m ou n ted in a 1 9 r ack via op tion al r ack m ou n t kit 2 4 Grounding and Wiring Recommendations Th e LIB3 0 4 LIB 3 0 6 can elim in ate th e effects of n oise d u e to EMI via p r op er gr ou n d in g Always r u n th e gr ou n d con n ection fr om th e gr ou n d scr ew to th e gr ...

Page 15: ...b cop y th e r u n n in g con figu r ation to th e star t u p con figu r ation c r estar t th e d evice in factor y d efau lt con figu r ation d Note th at th is r esets th e u n it IP ad d r ess Th e RESET b u tton can b e d isab led ign or ed v ia th e CLI Please r efer to th e CLI r efer en ce m an u al Note Restor in g factor y d efau lt can also b e p er for m ed b y m akin g a p h ysical loo...

Page 16: ...or it can b e u sed as a n or m a l d ata UNI NNI p or t See Con n ectin g Via th e MGMT Por t Web GUI on p age 1 5 By d efau lt PORT 1 is en ab led as a Man agem en t p or t with a d efau lt IP an d su b n et m ask See Factor y Defau lts on p age 1 6 Fu ll in str u ction s for d isa b lin g th e m an agem en t fu n ction an d h ow to u se th e p or t as a n or m al d ata p or t ar e p r ovid ed i...

Page 17: ... b p s P3 P6 LED P5 P6 on th e LIB 3 0 6 4 2 fib r e lin k statu s Wh en lit in gr een in d icates a 1 G fib r e lin k activity Wh en lit in am b er in d icates a 1 0 0 M fib r e lin k activity Wh en off in d icates n o fib r e lin k estab lish ed PWR LED Gr een Power LED On p ower ap p lied to th e PC b oar d Flash es Gr een d u r in g LIB 3 0 6 b oot u p S1 LED System Statu s LED Bi colou r Gr e...

Page 18: ... con n ector with 2 IN an d 2 OUT 1 0 3 0 VDC 4 0 m A m axim u m op tically isolated fr om m ain b oar d You can con n ect u p to two alar m in p u ts fr om exter n al d evices in you r en vir on m en t e g a fir e alar m a d oor sen sor a tem p er atu r e gau ge to th e alar m in p u t p or t on th e switch fr on t p an el Th e figu r e b elow sh ows th e location of th e alar m p in ou ts For ea...

Page 19: ... State LED behaviour Trigger setting Alarm relay out state Asserted Activ e Close r elay closed De asserted Not activ e Close r elay op en Asserted Activ e Op en r elay op en De asserted Not activ e Op en r elay closed Alarm In puts Wire state Trigger setting Alarm state LED behaviour En er gized Close Asserted Activ e De en er gized Close De asserted Not activ e En er gized Op en De asserted Not ...

Page 20: ...s Warning Visib le an d in visib le laser r a d iation wh en op en DO NOT star e in to th e b eam or view th e b eam d ir ectly with op tical in str u m en ts Failu r e to ob ser ve th is war n in g cou ld r esu lt in a n eye in ju r y or b lin d n ess Use of con tr ols ad ju stm en ts or th e p er for m an ce of p r oced u r es oth er th an th ose sp ecified h er ein m ay r esu lt in h azar d ou ...

Page 21: ...er t th e fib r e cab le en d s com p letely in to th e SFP as sh own b elow 6 In ser t th e SFP fu lly in to th e cage as sh own b elow 7 Switch Fu lly In ser ted SFP Rem oving SFPs 8 Attach an ESD p r even tive wr ist str ap to you r wr ist an d to a b ar e m etal gr ou n d ed su r face 9 Have a r ep lacem en t SFP or a tr an sceiver cage p lu g r ea d y as well as an an tistatic m at an d a r u...

Page 22: ...E u se a cr ossover or str aigh t th r ou gh cab le See figu r e b elow 2 9 2 Connecting Ethernet Cables 1 Locate or b u ild an IEEE 8 0 2 3 com p lian t cab le with m ale RJ 4 5 con n ector s in stalled at b oth en d s as sh own b elow 2 Con n ect th e RJ 4 5 con n ector at on e en d of th e cab le to th e LIB 3 0 6 RJ 4 5 p or t 3 Con n ect th e RJ 4 5 con n ector at th e oth er en d of th e cab...

Page 23: ...r ial Con sole Teln et or SSH 2 11 Connecting via the MGMT Port Web GUI Th e LIB 3 0 4 LIB 3 0 6 su p p or ts th ese Web b r owser s In ter n et Exp lor er Fir efox Google Ch r om e See th e Web User Gu id e or th e CLI Refer en ce m an u al for d etails on con figu r ation an d m an agem en t m eth od s To login u sin g th e ser ial in ter face e g Hyp er Ter m in al setu p u sin g th ese p ar am...

Page 24: ... Address Ipv6 Address En ab led 1 9 2 1 6 8 0 1 1 9 2 0 2 1 Note after p ower u p th e u n it h as DHCP en ab led If a DHCP ser ver is availab le th e u n it will ob tain an IP ad d r ess fr om th e DHCP ser ver If n o DHCP ser ver is availab le after 7 0 secon d s th e u n it will fa ll b ack to th e d efau lt IP ad d r ess of 1 9 2 1 6 8 0 1 2 4 Static IP configuration ...

Page 25: ...5 5 0 See th e LIB 3 0 6 CLI Refer en ce m an u al for CLI com m an d in for m ation for CLI d etails 4 To ver ify th e ch an ge you can log in to th e LIB 3 0 6 Web GUI u sin g IP ad d r ess 1 9 2 1 6 8 1 1 1 0 See th e LIB 3 0 6 Web User Gu id e for m or e in for m ation 2 13 Login using PuTTY Terminal Emulator Software 1 Star t a Pu TTY session In th e Pu TTY d ialog b ox in th e Host Nam e or ...

Page 26: ... 4 At th e Passwor d p r om p t p r ess th e En ter key to d isp lay th e p r om p t 5 At th e p r om p t en ter CLI com m an d s as d esir ed 2 15 Login Using the Web Interface 1 Lau n ch a web b r owser In ter n et Exp lorer Fir eFox 2 En ter th e u n it IP ad d r ess e g 1 9 2 1 6 8 0 1 in th e b r owser URL field 3 Pr ess th e En ter key to lau n ch th e login d ialog b o x 4 In th e u ser n a...

Page 27: ... ove You can en ab le or d isab le ou t of b an d m an agem en t on Por t 1 Por t 1 can b e op tion ally con figu red to su p p or t eith er ou t of b an d m an agem en t or it can b e u sed as a n or m a l d ata UNI NNI p or t By d efau lt Por t 1 is en ab led as a m an agem en t p or t with a d efau lt IP 1 9 2 1 6 8 0 1 2 4 an d su b n et m ask By d efau lt all p or ts a r e VLAN u n awar e an ...

Page 28: ...le sp an n in g tree on th e p or t d esign ated for Man agem en t Rem ove p vlan 1 fr om th e n ew in ter face an d d isab le d h cp for war d in g an d a d d p vlan 6 2 Ph ysically con n ect to th e n ewly d esign ated Man agem en t p or t 3 En ab le p vlan 1 for th e n ew p or t d esign ated as a d ata p or t 4 If n ecessar y en ab le sp an n in g tr ee on th e n ew d ata p or t interface Gigab...

Page 29: ...oduct Registration It is im p or tan t to register th e p r od u ct for th e followin g r eason s Softwar e Fir m war e Dr iver u p d ates Have access to all of ou r tr ain in g tools vid eos con ten t an d d own load s Tech n ical d ocu m en tation an d in for m ation ab ou t su p p or t assistan ce Receive em ail aler ts of n ew p r od u cts accor d in g to p er son al in ter est ...

Page 30: ...h e LIB 3 0 6 Web User Gu id e m an u al 7 Ch eck th e LIB 3 0 4 LIB 3 0 6 op er atin g p ar am eter s e g In for m ation CPU Load Log Detailed Log See th e Op er ation section of th e LIB 3 0 6 Web User Gu id e m an u al 8 If you can access th e u n it via Pu TTY or Hyp er Ter m in al b u t n ot via th e web in ter face in con fig m od e en ter th e d efau lt keep _ ip CLI com m an d an d tr y ac...

Page 31: ...for m ation Monitor Sy stem Inform ation Monitor Sy stem IP Status LED Statu s 4 Pr ovid e ad d ition al Mod el an d System in for m ation to you r Tech n ical Su p p or t Sp ecialist See th e Tr ou b lesh ootin g section ab ove You r Net2 Ed ge serv ice con tract n u m b er A d escrip tion of th e failu re A d escrip tion of an y action s alread y tak en to resolv e th e p rob lem e g ch an gin g...

Page 32: ...p rev iou s Retu rn Material Au th oriz ation RMA n u m b ers 4 Service Warranty and Tech Support 4 1 Contact Us Technical Support 4 4 3 4 5 0 1 3 0 0 3 0 exten sion 6 8 1 0 E Mail To ask a q u estion an ytim e sen d an e m ail to ou r tech n ical su p p or t staff at su p p or t n et2 ed ge com Address Net2 Ed ge Ltd Ku lite Hou se Str ou d ley Road Basin gstoke RG2 4 8 UG UK Tel 4 4 3 4 5 0 1 3 ...

Page 33: ... n ection with th e p er for m an ce of th e p r od u ct d eliver ed h er eu n d er Net2 Ed ge will in n o case cover d am ages ar isin g ou t of th e p r od u ct b ein g u sed in a n egligen t fash ion or m an n er Return Authorization To r etu r n a d efective p r od u ct for war r an ty cover age con tact Net2 Ed ge s tech n ical su p p or t d ep ar tm en t for a r etu r n au th or ization n u ...

Page 34: ...r es a USD3 0 0 ch ar ge p lu s actu al sh ip p in g costs to an d fr om th e cu stom er If th e r ep air is gr eater th an USD 3 0 0 0 0 an estim ate is issu ed to th e cu stom er for au th or ization of r ep air If n o au th or ization is ob tain ed or th e p r od u ct is d eem ed n on r ep air ab le Net2 Ed ge will r etain th e USD3 0 0 ser vice ch ar ge an d r etu r n th e p r od u ct to th e ...

Page 35: ...u es ap p r op r iées In accor d an ce with Eu r op ean Un ion Dir ective 2 0 0 2 9 6 EC of th e Eu r op ean Par liam en t an d of th e Cou n cil of 2 7 Jan u ar y 2 0 0 3 Net2 Ed ge will accep t p ost u sage r etu r n s of th is p r od u ct for p r op er d isp osal Th e con tact in for m ation for th is activity can b e fou n d in th e Con tact Us p or tion of th is d ocu m en t CAUTION RJ con n ...

Page 36: ...RIJK Dit ap p ar aat m oet in over een stem m in g m et d e veiligh eid svoor sch r iften wor d en geïn stalleer d Sécurité électrique IMPORTANT Cet éq u ip em en t d oit êtr e u tilisé con for m ém en t au x in str u ction s d e sécu r ité Sähköturvallisuus TÄRKEÄÄ Täm ä laite on asen n ettava tu r vaoh jeid en m u kaisesti Sicurezza elettrica IMPORTANTE q u esta ap p ar ecch iatu r a d eve esser...

Page 37: ...2 37 of 37 IMPORTANTE La in stalación d e este eq u ip o d eb er á llevar se a cab o cu m p lien d o con las p r ecau cion es d e segu r id ad Elsäkerhet OBS Alla n öd vän d iga för siktigh etsåtgär d er m åste vid tas n är d en n a u tr u stn in g an vän d s ...

Reviews: