FLEXNET BARB CONNECTOR 

ASSEMBLY INSTRUCTIONS 

 

1

FLEXNET

 AND FLEXNET

™ 

HP

BARB CONNECTOR

ASSEMBLY INSTRUCTIONS

Connecting a barb connector. Size 2"; 3"; 4"

1. 

Strictly ensure the pipe is 

cut perfectly straight

 during the cutting operation (

Fig. 1

).

When reconnecting a pipe to the connector, cut at least 1.5 cm (5/8") off the pipe end.

2. 

Insert the metal clamp onto the pipe (

Fig. 2

).

3. 

Make sure that the pipe inside surface is wet, so it will not stick to the rubber seal in the connector, and

move it from it's groove.

4. 

Make sure that the pipe is 

inserted all the way

 to the connector’s shoulder (

Fig. 3a

).

5. 

Make sure there is 

no gap

 between the metal clamp and the connector’s shoulder (

Fig. 3, 3a and 3b

).

No gap

Gap

Fig. 1

Fig. 2

Fig. 3

Fig. 3a

Fig. 3b

Summary of Contents for FLEXNET

Page 1: ...o the connector cut at least 1 5 cm 5 8 off the pipe end 2 Insert the metal clamp onto the pipe Fig 2 3 Make sure that the pipe inside surface is wet so it will not stick to the rubber seal in the con...

Page 2: ...sizes 2 Key size 16 40 mm 3 and 4 Key size 40 75 mm 6 Tighten forcefully Fig 6 Connecting a PVC cement adaptor Glue the adaptor according to the PVC cement manufacturer s instructions Netafim recomme...

Page 3: ...at the designated place Fig 13 2 Use a BSP NPT 1 2 tap to prepare the thread Fig 14 3 Connect the relevant accessory apply Teflon tape Fig 15 If needed retighten under water pressure Fig 13 Fig 14 Fi...

Page 4: ...at the metal clamp is exactly above the rubber seal Fig 4 6 Tighten forcefully Fig 8 No gap Connecting a barb connector Size 6 8 10 12 1 Strictly ensure the pipe is cut perfectly straight during the c...

Page 5: ...M D 2466 6 8 10 12 ISO 1452 160 mm 200 mm 250 mm 315 mm Connecting a PVC cement adaptor Glue the adaptor according to the PVC cement manufacturer s instructions Fig 9 and 10 Netafim recommends using a...

Page 6: ...rubber seal and the other exactly above the ribbed rim Fig 4 Fig 1 Fig 2 Connecting a high pressure barb connector Size 6 8 1 Strictly ensure the pipe is cut perfectly straight during the cutting oper...

Page 7: ...aptors ASTM D 2466 6 8 ISO 1452 160 mm 200 mm Connecting a PVC cement adaptor Glue the adaptor according to the PVC cement manufacturer s instructions Fig 9 and 10 Netafim recommends using a cleaning...

Reviews: