FLEXNET BARB CONNECTOR
ASSEMBLY INSTRUCTIONS
1
FLEXNET
™
AND FLEXNET
™
HP
BARB CONNECTOR
ASSEMBLY INSTRUCTIONS
Connecting a barb connector. Size 2"; 3"; 4"
1.
Strictly ensure the pipe is
cut perfectly straight
during the cutting operation (
Fig. 1
).
When reconnecting a pipe to the connector, cut at least 1.5 cm (5/8") off the pipe end.
2.
Insert the metal clamp onto the pipe (
Fig. 2
).
3.
Make sure that the pipe inside surface is wet, so it will not stick to the rubber seal in the connector, and
move it from it's groove.
4.
Make sure that the pipe is
inserted all the way
to the connector’s shoulder (
Fig. 3a
).
5.
Make sure there is
no gap
between the metal clamp and the connector’s shoulder (
Fig. 3, 3a and 3b
).
No gap
Gap
Fig. 1
Fig. 2
Fig. 3
Fig. 3a
Fig. 3b