A stand-alone configuration
Proceed to the next step. No action is required.
+
You have completed system-level diagnostics.
Resulted in some test failures
Determine the cause of the problem:
a. Exit Maintenance mode:
halt
After you issue the command, wait until the
system stops at the LOADER prompt.
b. Turn off or leave on the power supplies,
depending on how many controller modules are in
the chassis:
◦
If you have two controller modules in the
chassis, leave the power supplies turned on to
provide power to the other controller module.
◦
If you have one controller module in the
chassis, turn off the power supplies and
unplug them from the power sources.
c. Verify that you have observed all the
considerations identified for running system-level
diagnostics, that cables are securely connected,
and that hardware components are properly
installed in the storage system.
d. Boot the controller module you are servicing,
interrupting the boot by pressing
Ctrl-C
when
prompted to get to the Boot menu:
◦
If you have two controller modules in the
chassis, fully seat the controller module you
are servicing in the chassis.
The controller module boots up when fully
seated.
◦
If you have one controller module in the
chassis, connect the power supplies, and then
turn them on.
e. Select Boot to maintenance mode from the menu.
f. Exit Maintenance mode by entering the following
command:
halt
After you issue the command, wait until the
system stops at the LOADER prompt.
g. Rerun the system-level diagnostic test.
998
Summary of Contents for AFF A700
Page 4: ...AFF and FAS System Documentation 1...
Page 208: ...3 Close the controller module cover and tighten the thumbscrew 205...
Page 248: ...2 Close the controller module cover and tighten the thumbscrew 245...
Page 308: ...Power supply Cam handle release latch Power and Fault LEDs Cam handle 305...
Page 381: ...Power supply Cam handle release latch Power and Fault LEDs Cam handle 378...
Page 437: ...1 Locate the DIMMs on your controller module 434...
Page 605: ...602...
Page 1117: ...3 Close the controller module cover and tighten the thumbscrew 1114...
Page 1157: ...2 Close the controller module cover and tighten the thumbscrew 1154...
Page 1228: ...Power supply Cam handle release latch Power and Fault LEDs Cam handle 1225...
Page 1300: ...Power supply Cam handle release latch Power and Fault LEDs Cam handle 1297...
Page 1462: ...Installing SuperRail to round hole four post rack 1459...
Page 1602: ...1599...
Page 1630: ...1627...
Page 1634: ...Orange ring on horizontal bracket Cable chain 1631...
Page 1645: ...Guide rail 1642...
Page 1669: ...Attention LED light on 1666...