provided, contact NetApp Support.
b. Verify the
Restored
column shows
yes
for all authentication keys:
security key-manager key
query
c. Verify that the
Key Manager
type shows
onboard
, manually backup the OKM information.
d. Go to advanced privilege mode and enter
y
when prompted to continue:
set -priv advanced
e. Enter the command to display the key management backup information:
security key-manager
onboard show-backup
f. Copy the contents of the backup information to a separate file or your log file. You’ll need it in disaster
scenarios where you might need to manually recover OKM.
g. Return to admin mode:
set -priv admin
h. You can safely shutdown the node.
Shut down the impaired controller - AFF A220 and FAS2700
Option 1: Most configurations
After completing the NVE or NSE tasks, you need to complete the shutdown of the
impaired node.
Steps
1. If the impaired node isn’t at the LOADER prompt:
If the impaired node displays…
Then…
Waiting for giveback...
Press Ctrl-C, and then respond
y
when prompted.
System prompt or password
prompt (enter system password)
Take over or halt the impaired node:
• For an HA pair, take over the impaired node from the healthy
node:
storage failover takeover -ofnode
`impaired_node_name`
When the impaired node shows Waiting for giveback…, press
Ctrl-C, and then respond
y
.
2. From the LOADER prompt, enter:
printenv
to capture all boot environmental variables. Save the output
to your log file.
This command may not work if the boot device is corrupted or non-functional.
Option 2: Controller is in a MetroCluster
After completing the NVE or NSE tasks, you need to complete the shutdown of the
impaired node.
98
Summary of Contents for AFF A700
Page 4: ...AFF and FAS System Documentation 1...
Page 208: ...3 Close the controller module cover and tighten the thumbscrew 205...
Page 248: ...2 Close the controller module cover and tighten the thumbscrew 245...
Page 308: ...Power supply Cam handle release latch Power and Fault LEDs Cam handle 305...
Page 381: ...Power supply Cam handle release latch Power and Fault LEDs Cam handle 378...
Page 437: ...1 Locate the DIMMs on your controller module 434...
Page 605: ...602...
Page 1117: ...3 Close the controller module cover and tighten the thumbscrew 1114...
Page 1157: ...2 Close the controller module cover and tighten the thumbscrew 1154...
Page 1228: ...Power supply Cam handle release latch Power and Fault LEDs Cam handle 1225...
Page 1300: ...Power supply Cam handle release latch Power and Fault LEDs Cam handle 1297...
Page 1462: ...Installing SuperRail to round hole four post rack 1459...
Page 1602: ...1599...
Page 1630: ...1627...
Page 1634: ...Orange ring on horizontal bracket Cable chain 1631...
Page 1645: ...Guide rail 1642...
Page 1669: ...Attention LED light on 1666...