7. Complete the installation of the controller module:
a. Plug the power cord into the power supply, reinstall the power cable locking collar, and then
connect the power supply to the power source.
b. Firmly push the controller module into the chassis until it meets the midplane and is fully seated.
The locking latches rise when the controller module is fully seated.
Do not use excessive force when sliding the controller module into the chassis to
avoid damaging the connectors.
The controller module begins to boot as soon as it is fully seated in the chassis. Be prepared to
interrupt the boot process.
c. Rotate the locking latches upward, tilting them so that they clear the locking pins, and then lower
them into the locked position.
d. If you have not already done so, reinstall the cable management device.
8. Interrupt the boot process by pressing Ctrl-C to stop at the LOADER prompt.
If you miss this message, press Ctrl-C, select the option to boot to Maintenance mode, and then
halt
the node to boot to LOADER.
9. Although the environment variables and bootargs are retained, you should check that all required boot
environment variables and bootargs are properly set for your system type and configuration using the
printenv bootarg name
command and correct any errors using the
setenv
variable-name
<value>
command.
a. Check the boot environment variables:
▪
bootarg.init.boot_clustered
▪
partner-sysid
▪
bootarg.init.flash_optimized
for AFF C190/AFF A220 (All Flash FAS)
▪
bootarg.init.san_optimized
for AFF A220 and All SAN Array
▪
bootarg.init.switchless_cluster.enable
b. If External Key Manager is enabled, check the bootarg values, listed in the
kenv
ASUP output:
▪
bootarg.storageencryption.support
<value>
▪
bootarg.keymanager.support
▪
kmip.init.interface
<value>
▪
kmip.init.ipaddr
<value>
▪
kmip.init.netmask
<value>
▪
kmip.init.gateway
<value>
c. If Onboard Key Manager is enabled, check the bootarg values, listed in the
kenv
ASUP output:
▪
bootarg.storageencryption.support
<value>
▪
`bootarg.keymanager.support
<value>`
▪
bootarg.onboard_keymanager
<value>
1330
Summary of Contents for AFF A700
Page 4: ...AFF and FAS System Documentation 1...
Page 208: ...3 Close the controller module cover and tighten the thumbscrew 205...
Page 248: ...2 Close the controller module cover and tighten the thumbscrew 245...
Page 308: ...Power supply Cam handle release latch Power and Fault LEDs Cam handle 305...
Page 381: ...Power supply Cam handle release latch Power and Fault LEDs Cam handle 378...
Page 437: ...1 Locate the DIMMs on your controller module 434...
Page 605: ...602...
Page 1117: ...3 Close the controller module cover and tighten the thumbscrew 1114...
Page 1157: ...2 Close the controller module cover and tighten the thumbscrew 1154...
Page 1228: ...Power supply Cam handle release latch Power and Fault LEDs Cam handle 1225...
Page 1300: ...Power supply Cam handle release latch Power and Fault LEDs Cam handle 1297...
Page 1462: ...Installing SuperRail to round hole four post rack 1459...
Page 1602: ...1599...
Page 1630: ...1627...
Page 1634: ...Orange ring on horizontal bracket Cable chain 1631...
Page 1645: ...Guide rail 1642...
Page 1669: ...Attention LED light on 1666...