b. If automatic drive assignment is enabled, disable it:
storage disk option modify -node
node_name -autoassign off
You must disable automatic drive assignment on both controller modules.
2. Properly ground yourself.
3. Gently remove the bezel from the front of the platform.
4. Identify the failed disk drive from the system console warning message and the illuminated fault LED
on the disk drive
5. Press the release button on the disk drive face.
Depending on the storage system, the disk drives have the release button located at the top or on the
left of the disk drive face.
For example, the following illustration shows a disk drive with the release button located on the top of
the disk drive face:
The cam handle on the disk drive springs open partially and the disk drive releases from the midplane.
6. Pull the cam handle to its fully open position to unseat the disk drive from the midplane.
7. Slide out the disk drive slightly and allow the disk to safely spin down, which can take less than one
minute, and then, using both hands, remove the disk drive from the disk shelf.
8. With the cam handle in the open position, insert the replacement disk drive into the drive bay, firmly
pushing until the disk drive stops.
Wait a minimum of 10 seconds before inserting a new disk drive. This allows the system
to recognize that a disk drive was removed.
If your platform drive bays are not fully loaded with drives, it is important to place the
replacement drive into the same drive bay from which you removed the failed drive.
Use two hands when inserting the disk drive, but do not place hands on the disk drive
boards that are exposed on the underside of the disk carrier.
9. Close the cam handle so that the disk drive is fully seated into the midplane and the handle clicks into
place.
Be sure to close the cam handle slowly so that it aligns correctly with the face of the disk drive..
10. If you are replacing another disk drive, repeat Steps 4 through 9.
11. Reinstall the bezel.
12. If you disabled automatice drive assignment in Step 1, then, manually assign drive ownership and then
reenable automatic drive assignment if needed.
a. Display all unowned drives:
storage disk show -container-type unassigned
You can enter the command on either controller module.
1490
Summary of Contents for AFF A700
Page 4: ...AFF and FAS System Documentation 1...
Page 208: ...3 Close the controller module cover and tighten the thumbscrew 205...
Page 248: ...2 Close the controller module cover and tighten the thumbscrew 245...
Page 308: ...Power supply Cam handle release latch Power and Fault LEDs Cam handle 305...
Page 381: ...Power supply Cam handle release latch Power and Fault LEDs Cam handle 378...
Page 437: ...1 Locate the DIMMs on your controller module 434...
Page 605: ...602...
Page 1117: ...3 Close the controller module cover and tighten the thumbscrew 1114...
Page 1157: ...2 Close the controller module cover and tighten the thumbscrew 1154...
Page 1228: ...Power supply Cam handle release latch Power and Fault LEDs Cam handle 1225...
Page 1300: ...Power supply Cam handle release latch Power and Fault LEDs Cam handle 1297...
Page 1462: ...Installing SuperRail to round hole four post rack 1459...
Page 1602: ...1599...
Page 1630: ...1627...
Page 1634: ...Orange ring on horizontal bracket Cable chain 1631...
Page 1645: ...Guide rail 1642...
Page 1669: ...Attention LED light on 1666...